Anais do Seminário de Aciaria, Fundição e Metalurgia de Não-ferrosos


ISSN 2594-5300

46º Seminário de Aciaria - Internacional vol. 46, num.46 (2015)


Título

AUMENTO DA CONFIABILIDADE OPERACIONAL E DISPONIBILIDADE DO FEA DA VOTORANTIM RESENDE ATRAVÉS DO USO DAS TECNOLOGIAS DOUBLE SIDE E PROTECT BLOCK

OPERATIONAL RELIABILITY INCREASE AND AVAILABILITY OF VOTORANTIM'S EAF THROUGH THE USE OF DOUBLE SIDE AND PROTECK BLOCK TECHNOLOGIES

DOI

10.5151/1982-9345-27005

Downloads

Baixar Artigo 1316 Downloads

Resumo

A aciaria elétrica da Votorantim Siderurgia em Resende, possui um FEA de capacidade de 100 t, transformador de 100+20 MVa, equipado com 05 injetores convencionais de oxigênio e 03 injetores convencionais de carbono. Em função do elevado aporte de energia química e elétrica inserida no processo os painéis refrigerados, e demais equipamentos localizados em determinadas regiões do FEA, são termicamente mais solicitados e requerem maior atenção e rigor do sistema de manutenção preventiva, a fim de evitar interrupções operacionais do processo. Através da análise de dados históricos, detectou-se que a região do FEA de maior criticidade e intervenções de manutenção era o painel refrigerado P-10. As tecnologias Double Side e Protect Block foram instaladas em substituição ao painel refrigerado P-10 com o objetivo de aumentar a confiabilidade operacional do FEA, reduzir os riscos de acidentes operacionais, aumentar a disponibilidade dos equipamentos nesta posição, reduzir o número de intervenções de manutenção (preventiva e corretiva), reduzir os custos de manutenção (preventiva e corretiva) e consequentemente reduzir o power off do FEA.

 

The steel meltshop of Votorantim Resende has an EAF with 100 t capacity, a 100+20 MVa electrical transformer, equipped with 05 conventional oxygen injectors and 03 conventional carbon injectors. Due to the high chemical and electrical energy use in the process the water cooled panels, and others equipments located in the hot spots of the furnace are most thermal stressed and needs more attention and prior maintenance preventive system to avoid the EAF interruptions. The analysis of historical data shown that the most critical water cooled panel of the EAF was a Position 10. In order to increase the operational reliability, reduce the accidents risks, increased the availability, reduce maintenance interventions, reduce the costs and reduce power off time, the panel in the Position 10 was replaced by Double Side and Protect Block technologies.

Palavras-chave

Double side, Protect block, Aumento de confiabilidade, Redução de custos

Double Side, Protect Block, Reliability increase, Cost reduction

Como citar

Wandekoken, Thiago Pinto; Coutinho, Pedro Henrique; Guimarães, Júlio César; Costa, Claysson Pereira da; Cerqueira, José Fernando. AUMENTO DA CONFIABILIDADE OPERACIONAL E DISPONIBILIDADE DO FEA DA VOTORANTIM RESENDE ATRAVÉS DO USO DAS TECNOLOGIAS DOUBLE SIDE E PROTECT BLOCK , p. 690-699. In: 46º Seminário de Aciaria - Internacional, Rio de Janeiro, 2015.
ISSN: 2594-5300 , DOI 10.5151/1982-9345-27005