AVALIAÇÃO DA RESISTÊNCIA À CORROSÃO INTERGRANULAR DO AÇO INOXIDÁVEL AUSTENÍTICO ASTM F138

INTERGRANULAR CORROSION RESISTANCE EVALUATION OF ASTM F138 STAINLESS STEEL

DOI

10.5151/2594-5327-39633

Downloads

Baixar Artigo 14 Downloads

Resumo

O aço inoxidável austenítico ASTM F138 é utilizado na forma de placas e parafusos como implantes cirúrgicos permanentes. Por conta de sua aplicação crítica, estudos sobre sua susceptibilidade à corrosão intergranular devem ser realizados de modo a garantir a ausência de fases deletérias. Nesse sentido, amostras do aço ASTM F138 foram envelhecidas por tempos de até 24 h a 675 °C. Ensaios em solução de ácido oxálico de acordo com a norma ASTM A262 método A (A262/A) associado a utilização da técnica de reativação potenciocinética de duplo ciclo (DL-EPR) foram realizados. A faixa de varredura, parâmetro de ensaio do DL-EPR, foi ajustada para permitir a avaliação do aço ASTM F138. Os resultados do ensaio A262/A mostraram a alteração da morfologia microestrutural de step, para dual e, finalmente, ditch com o aumento no tempo de envelhecimento. Adicionalmente, ensaios de DL-EPR exibiram ausência de reativação para as amostras com morfologia step, mas presença de reativação para as amostras com morfologias dual e ditch. Nesse sentido, a redução na faixa de varredura permitiu a correlação e concordância entre as técnicas A262/A e DL-EPR na avaliação da susceptibilidade à corrosão intergranular de aços inoxidáveis austeníticos com teor de carbono reduzido, em especial o ASTM F138

 

ASTM F138 austenitic stainless steel is used in the form of plates and screws as permanent surgical implants. Due to its critical application, studies on the susceptibility to intergranular corrosion must be carried out to ensure the absence of deleterious phases. In this regard, ASTM F138 steel samples were aged for up to 24 h at 675 ºC. Oxalic acid solution test according to ASTM A262 method A (A262/A) associated with the use of the Double-Loop Electrochemical Potentiokinetic Reaction technique (DL-EPR) were performed. The sweep range, one of the control parameters of the DL-EPR test, was adjusted to allow the evaluation of ASTM F138 steel. A262/A test results showed a change in microstructural morphology from step, to dual, and, finally, ditch with increasing aging time. In addition, DL-EPR test showed absence of reactivation for samples with step morphology, but presence of reactivation for samples with dual and ditches. The correlation and agreement between A262/A and DL-EPR tests after the sweep range adjustment allowed to evaluate the susceptibility to intergranular corrosion of low carbon austenitic stainless steels like ASTM F138

Palavras-chave

ASTM F138; Corrosão intergranular; ASTM A262; DL-EPR

ASTM F138; Intergranular corrosion; ASTM A262; DL-EPR