Anais do Congresso Anual da ABM


ISSN 2594-5327

73º Congresso Anual da ABM vol. 73, num.73 (2018)


Título

AVALIAÇÃO DOS PARÂMETROS DE ENSAIO DE DUREZA DINÂMICA EM ESTRUTURAS DENTARIAS E COMPÓSITO RESINOSO RESTAURADOR

EVALUATION OF DYNAMIC HARDNESS TEST PARAMETERS IN DENTAL STRUCTURES AND RESIN RESTORATIVE COMPOSITE

DOI

10.5151/1516-392X-31603

Downloads

Baixar Artigo 168 Downloads

Resumo

O objetivo deste estudo foi entender e padronizar os parâmetros de carga utilizados em ensaios de dureza dinâmica em escala micrométrica para materiais biológicos (dentina) e materiais restauradores (compósito resinoso). Para os ensaios dos tecidos biológicos foram utilizados terceiros molares humanos inclusos, cortados no sentido longitudinal, polidos e embutidos em resina acrílica. O compósito resinoso nanoparticulado utilizado possui o nome comercial Filtek Z350 XT, tendo sido condensada em uma matriz retangular. Devido às propriedades viscoelásticas tanto da dentina quanto do material restaurador, parâmetros como carga e tempo de permanência da penetração poderiam influenciar nos resultados obtidos. Analisou-se visualmente os padrões de imagem de impressão resultantes dos ensaios, tendo sido então padronizado valores de carga e tempo de permanência de 500mN e 0s e 1N e 15s, para a dentina e o compósito respectivamente, devido a forma correta do formato do penetrador na impressão. Na dentina foi possível observar que o material aparentemente não sofria alterações quando cargas mais altas eram aplicadas, diferente de quando eram utilizadas cargas mais baixas. Concluindo-se assim que valores diferentes de carga e tempo de permanência do penetrador podem gerar valores diferentes de módulo de elasticidade nas estruturas viscoelásticas estudadas.

 

The aim of this study was to understand and standardize the load parameters used in dynamic micrometer scale hardness tests for biological materials (dentin) and restorative materials (resin composite). For the biological tissue assays, third human molars included were used, cut lengthwise, polished and embedded in acrylic resin. The nanoparticulate resin composite used has the trade name Filtek Z350 XT and has been condensed into a rectangular matrix. Due to the viscoelastic properties of both dentin and restorative material, parameters such as loading and residence time of penetration could influence the results obtained. The print image patterns resulting from the tests were visually analyzed, and loading and residence times of 500mN and 0s and 1N and 15s were standardized for the dentin and composite respectively, due to the correct shape of the penetrator shape on the print. In the dentin it was possible to observe that the material apparently did not change when higher loads were applied, different from when lower loads were used. It is concluded that different values of load and residence time of the penetrator can generate different values of modulus of elasticity in the studied viscoelastic structures.

Palavras-chave

Compósito resinoso; Ensaio de dureza; Módulo de elasticidade; Dentina.

Composite Resin; Hardness test; Modulus of elasticity; Dentin.

Como citar

Teixeira, Agatha Borges; Melo-Silva, Tereza Cristina Favieri; Melo-Silva, Cláudio Luís de; Carvalho, Eric Costa; Nunes, Adriana Marques; Gouvêa, Jayme Pereira. AVALIAÇÃO DOS PARÂMETROS DE ENSAIO DE DUREZA DINÂMICA EM ESTRUTURAS DENTARIAS E COMPÓSITO RESINOSO RESTAURADOR , p. 1234-1239. In: 73º Congresso Anual da ABM, São Paulo, 2018.
ISSN: 2594-5327 , DOI 10.5151/1516-392X-31603