Anais dos Seminários de Redução, Minério de Ferro e Aglomeração


ISSN 2594-357X

Título

COMPARAÇÃO ENTRE OS CUSTOS DAS TÉCNICAS ANALÍTICAS DE ESPECTROMETRIA DE FLUORESCÊNCIA DE RAIOS-X: PASTILHA PRENSADA VS PASTILHA FUNDIDA

COMPARISON AMONG THE COSTS OF THE ANALYTICAL TECHNIQUES OF SPECTROMETRY OF FLUORESCENCE OF X-RAY: PRESSED POWDER VS GLASS DISK

DOI

10.5151/2594-357X-00014

Downloads

Baixar Artigo 180 Downloads

Resumo

O presente trabalho tem o objetivo de apresentar um estudo detalhado comparando o custo entre as duas principais técnicas de análise de minério de ferro por espectrometria de fluorescência de raios-X (pastilha prensada e pastilha fundida). Foram considerados não só os componentes de custo diretamente envolvidos, mas todo custo de implantação/manutenção de cada técnica. Devido à diversidade de fatores que influenciam nesta avaliação foram adotadas algumas premissas de maneira a tornar as comparações mais coerentes. Entre elas as mais representativas estão relacionadas aos custos atrelados à mão de obra indireta e às instalações prediais, que não foram contabilizados. Apesar da técnica de pastilha prensada requerer mais controles e um número maior de curvas, o estudo mostrou que ela é mais viável, em termos de custos (80% mais barato que a pastilha fundida), quando grandes quantidades de amostras são analisadas. Como estudo de caso, também foi avaliado a utilização da técnica de pastilha fundida calcinada, aliada à utilização de padrões internos, com intuito de redução dos custos para viabilizar economicamente a utilização da técnica. Esse trabalho buscou subsidiar a decisão a ser tomada, sob a ótica dos custos envolvidos em cada uma das técnicas analíticas estudadas: pastilha prensada versus pastilha fundida.

 

The present work has the objective of presenting a detailed study comparing the cost among the two main techniques of iron ore analysis for spectrometry of fluorescence of X-ray (pressed powder and glass disk). Were considered not only the cost components directly involved, but every implantation/maintenance cost of each technique. Due to the diversity of factors that influence in this evaluation some were adopted way premises to turn the most coherent comparisons. Among them the most representative are related to the costs harnessed by hand of indirect work and to the property facilities that were not counted. In spite of the technique of pressed powder to request more controls and a larger number of curves, the study showed that it is more viable, in terms of costs (80% cheaper than the glass disk), when great amounts of samples are analyzed. As case study, also was evaluated the use of the technique glass disk ignited, allied to the use of internal standard, with intention of reduction of the costs to make possible the use of the technique economically. This work looked for to subsidize the decision to be taken, under the optics of the costs involved in each one of the studied analytical techniques: pressed powder vs glass disk.

Palavras-chave

Custo; Raios-X; Pastilha prensada; Pastilha fundida.

Cost; X-ray; Pressed powder; Glass dis.

Como citar

Fazollo, Francisco Magalhães; Joncew, Liana. COMPARAÇÃO ENTRE OS CUSTOS DAS TÉCNICAS ANALÍTICAS DE ESPECTROMETRIA DE FLUORESCÊNCIA DE RAIOS-X: PASTILHA PRENSADA VS PASTILHA FUNDIDA , p. 69-83. In: 41º Ironmaking and Raw Materials Seminar and 12º Brazilian Symposium on Iron Ore, Vila Velha, 2011.
ISSN: 2594-357X , DOI 10.5151/2594-357X-00014