Anais dos Seminário de Energia, Utilidades e Gases Industriais


ISSN 2594-3626

Título

CONTROLE INTEGRADO DE NÍVEL DO TANQUE 108 DO STRA COM OS POÇOS DE CAREPAS DA LAMINAÇÃO

LEVEL INTEGRATED CONTROL FOR SCALE PITS ROLLING MILLS

DOI

10.5151/2594-3626-0008

Downloads

Baixar Artigo 34 Downloads

Resumo

O trabalho inicia explicando o processo de recirculação das águas das laminações, fornecendo dados sobre as unidades envolvidas, fazendo um relato sobre os problemas operacionais que vinham ocorrendo na sub-unidade de recirculação denominada STRA, com enfoque para o transbordo do tanque de recebimento no 108 e o problema de impacto ambiental gerado, com a consequente abertura de meta ambiental junto à Cetesb para que o problema fosse resolvido. Em seguida, mostramos a estratégia adotada para solução do problema, comentando os objetivos que pretendíamos alcançar ao adotar a solução finalmente escolhida. Serão detalhadas a seguir, as principais dificuldades que tiveram que ser vencidas durante a implantação do sistema, com enfoque para as interferências na comunicação e reformas elétricas nos painéis existentes, além da implementação de novos pontos de monitoração. No capítulo final do trabalho, são destacadas as características técnicas do sistema de controle integrado de nível entre os poços, a opção preservada de comando local e as telas de operação pelo sistema remoto, através da estação de operação da unidade STRA. Concluindo, comentamos os ajustes que estão sendo feitos na fase de implantação, para atender às necessidades de adequação do sistema, em face de alterações no fluxo de produção, mudanças em alguns equipamentos envolvidos etc.

 

The work begins explaining the waters recirculation process of rolling mills, supplying data about the involved units, making a report about operational problems that were happening in the sub unit denominated STRA, with focus for the reception tank 108 overflow and the problem that generated environmental impact, with the consequent opening of environmental compromise to Cetesb for to resolve the problem. Soon afterwards, we showed the strategy adopted for solution the problem, commenting the objectives that we intended to reach when adopting the finally solution chosen. They will be detailed to proceed, the main difficulties that we had to be due during the implantation of the system, with focus for the interferences in the communication and electric reforms in the existent panels, and the implementation of new monitoration points. In the final chapter, it will be to destache the technical characteristics of the scale pits integrated control system , the preserved option of local command and the operation screens for remote system, through the STRA operation. Concluding, we commented about the adjustments that are being done in the implantation phase, to assist the needs of system adaptation, in face of alterations in the production flow, changes in some involved equipments etc.

Palavras-chave

Wireless; Nível.

Wireless; Level.

Como citar

Menna, Antonio Gilberto Fernandes. CONTROLE INTEGRADO DE NÍVEL DO TANQUE 108 DO STRA COM OS POÇOS DE CAREPAS DA LAMINAÇÃO , p. 56-57. In: 28º Seminário de Balanços Energéticos Globais e Utilidades e 22º Encontro de Produtores e Consumidores de Gases Industrais, Vitória, 2007.
ISSN: 2594-3626 , DOI 10.5151/2594-3626-0008