Anais dos Seminários de Redução, Minério de Ferro e Aglomeração


ISSN 2594-357X

23º Seminário de Mineração vol. 23, num.23 (2024)


Título

DEFINIÇÃO DOS LIMITES DE CONTROLE PARA AS VARIÁVEIS CRÍTICAS DA FLOTAÇÃO DA USINA DE CONCEIÇÃO II

DEFINITION OF CONTROL LIMITS FOR THE CRITICAL VARIABLES OF FLOTATION AT THE CONCEIÇÃO II PLANT

DOI

10.5151/2594-357X-41473

Downloads

Baixar Artigo 4 Downloads

Resumo

BUSCANDO IDENTIFICAR AS VARIáVEIS DO PROCESSO DA FLOTAçãO REVERSA DO QUARTZO QUE APRESENTAM MAIOR INFLUêNCIA NO TEOR DE SIO2 NO CONCENTRADO A, ASSIM COMO DEFINIR OS RESPECTIVOS LIMITES DE CONTROLE PARA OBTENçãO DE UM PRODUTO COM TEOR DE SIO2 INFERIOR à META DE 1,28%, FORAM DESENVOLVIDOS MODELOS DE PREDIçãO DESTE PARâMETRO COM BASE NAS VARIáVEIS DE PROCESSO, APLICANDO-SE O MéTODO SHAP AO MODELO DE MELHOR DESEMPENHO. AS CINCO VARIáVEIS DE MAIOR INFLUêNCIA NO TEOR SIO2 DO CONCENTRADO, EM ORDEM DE IMPORTâNCIA, E SUAS RESPECTIVAS FAIXAS óTIMAS DE OPERAçãO, SãO: O NíVEL DE ESPUMA NA ETAPA CLEANER I (< 45 CM); O TEOR DE MGO NO ROM (< 0,125%); O NíVEL DE ESPUMA NA ETAPA ROUGHER I (> 45CM); O NíVEL DE ESPUMA NA ETAPA RECLEANER (> 23 CM) E A DOSAGEM DE AMIDO (< 550 G/T). CABE SALIENTAR QUE ESTES LIMITES NãO SãO DETERMINíSTICOS, MAS SIM ESTABELECEM A FAIXA DE OPERAçãO DE CADA ATRIBUTO PARA O QUAL EXISTE MAIOR PROBABILIDADE DE OBTENçãO DE CONCENTRADO CONFORME A ESPECIFICAçãO DE QUALIDADE.

 

IN ORDER TO IDENTIFY THE FLOTATION PROCESS CRITICAL VARIABLES, WHICH HAVE THE GREATEST INFLUENCE ON THE SIO2 CONTENT IN THE CONCENTRATE OF THIS STAGE, AS WELL AS THE RESPECTIVE CONTROL LIMITS FOR OBTAINING A PRODUCT WITH A SIO2 CONTENT BELOW THE TARGET OF 1.28%, MODELS WERE DEVELOPED TO PREDICT THE SIO2 CONTENT IN THE CONCENTRATE BASED ON THE PROCESS VARIABLES. THE SHAP METHOD WAS APPLIED TO THE BEST-PERFORMING MODEL. THE FIVE VARIABLES WITH THE GREATEST INFLUENCE ON THE SIO2 CONTENT IN THE CONCENTRATE, IN ORDER OF IMPORTANCE, AND THEIR RESPECTIVE OPTIMAL OPERATING RANGES, ARE: THE FOAM LEVEL IN THE CLEANER I STAGE (< 45 CM); THE MGO CONTENT IN THE ROM (< 0.125%); THE FOAM LEVEL IN THE ROUGHER I STAGE (> 45 CM); THE FOAM LEVEL IN THE RECLEANER STAGE (> 23 CM); AND THE STARCH DOSAGE (< 550 G/T). IT IS IMPORTANT TO NOTE THAT THESE LIMITS ARE NOT DETERMINISTIC, BUT RATHER ESTABLISH THE OPERATING RANGE FOR EACH ATTRIBUTE FOR WHICH THERE IS A HIGHER PROBABILITY OF OBTAINING A CONCENTRATE THAT MEETS THE QUALITY SPECIFICATIONS..

Palavras-chave

Minério de Ferro; Flotação; Controle de Processo

Iron ore; Flotation; Process control.

Como citar

FERREIRA, RODRIGO FINA; TEIXEIRA, FABIANA MARIA; VARGAS, NATHÁLIA. DEFINIÇÃO DOS LIMITES DE CONTROLE PARA AS VARIÁVEIS CRÍTICAS DA FLOTAÇÃO DA USINA DE CONCEIÇÃO II , p. 708-717. In: 23º Seminário de Mineração, São Paulo, Brasil, 2024.
ISSN: 2594-357X , DOI 10.5151/2594-357X-41473