Título

ENSAIOS ACELERADOS DE CORROSÃO EM UM EQUIPAMENTO SALT SPRAY

ACCELERATED CORROSION TESTS IN A SALT SPRAY EQUIPMENT

DOI

10.5151/2594-5327-34457

Downloads

Baixar Artigo 12 Downloads

Resumo

A CORROSÃO AFETA A INTEGRIDADE DO MATERIAL DE MANEIRA IRREVERSÍVEL E AFETA O SEU USO POR UMA EMPRESA DEVIDO A UMA DIMINUIÇÃO GRADUAL NA DISPONIBLIDADE DE EQUIPAMENTOS E INSTALAÇÕES. POR ESSE MOTIVO, EM BUSCA DA AVALIAÇÃO DO DESEMPENHO DE MATERIAIS IMPOSTOS A CONDIÇÕES FAVORÁVEIS DE SERVIÇO, A OCORRÊNCIA DO FENÔMENO DE CORROSÃO, OS ENSAIOS LABORATORIAIS DE CORROSÃO ACALERADA SÃO O ESTADO DA ARTE, POIS REPRESENTAM CONDIÇÕES PADRONIZADAS E REPLICÁVEIS QUE PERMITEM UMA AVALIAÇÃO APÓS UM CURTO PERÍODO DE TESTE. NESSE CONTEXTO, O PRESENTE TRABALHO BUSCA CONSOLIDAR UM PROJETO REALIZADO SEGUINDO AS NORMAS ISO 9227, ASTM B 117 E DIN 50 021 ALIADO A VISITAS TÉCNICAS EM WEBSITES A CATÁLOGOS SOMADOS A NORMA ABNT NBR 8094. PORTANTO CORPOS DE PROVA PADRÃO ADQUIRIDOS JUNTO A PSA FORAM EXPOSTOS EM UMA CÂMARA DE NÉVOA SALINA DURANTE UM PERÍODO DE 48 HORAS, FEITO OS TESTES A CÂMARA PROJETADA SE PROVOU EFETIVA E TODAS AS PERDAS DE MASSA ANOTADAS ESTAVAM DENTRO DOS PARÂMETROS NORMATIVOS ESTABELECIDOS.

 

CORROSION AFFECTS THE INTEGRITY OF THE MATERIAL IN AN IRREVERSIBLE MANNER AND AFFECTS THE COMPANY’S USE DUE TO A GRADUAL DECREASE IN THE AVAILABILITY OF EQUIPMENT AND FACILITIES. FOR THIS REASON, IN SEARCH OF EVALUATING THE PERFOMANCE OF MATERIALS IMPOSED TO FAVORABLE CONDITIONS OF SERVICE THE OCCURRENCE OF THE PHENOMENON OF CORROSION, LABORATORY TESTS OF ACCELERATED CORROSION ARE THE STATE OF THE AS THEY REPRESENT STANDARDIZED AND REPLICABLE CONDITIONS ALLOWING AN EVALUATION TO BE MADE AFTER A SHORT PERIOD OF TESTING. IN THIS CONTEXT, THE PRESENT WORK AIMS TO CONSOLIDATE A PROJECT MADE FOLLOWING THE STANDARD OF ISO 9227, ASTM B 117 AND DIN 50 021 ALLIED TO TECHNICAL VISITS WITH SEARCHES ON WEBSITES AND CATALOGS ADDED TO THE ABNT NBR 8094 STANDARD. THEREFORE, SPECIMENS ACQUIRED TOGETHER WITH PSA WERE EXPOSED TO A SALT SPRAY FOG CHAMBER IN A PERIOD OF 48 HOURS, ONCE THE TESTS WERE DONE PROVED THE CHAMBER PROJECTED WAS EFFECTIVE AND ALL THE MASS LOSSES RECORDED WERE WITHIN THE ESTABLISHED BY THE STANDARDS PARAMETERS.

Palavras-chave

Névoa salina, Corrosão, ISO 9227, Perda de massa.

Salt Spray fog, Corrosion, ISO 9227, Mass loss.

Como citar

Neuba, Lucas de Mendonça. ENSAIOS ACELERADOS DE CORROSÃO EM UM EQUIPAMENTO SALT SPRAY , p. 342-354. In: 75° Congresso Anual da ABM, São Paulo, 2022.
ISSN: 2594-5327 , DOI 10.5151/2594-5327-34457