Anais dos Seminário de Energia, Utilidades e Gases Industriais


ISSN 2594-3626

Título

ESTABILIDADE NA ETAPA DE DECANTAÇÃO DO SISTEMA DE ÁGUA COM CONTATO

STABILITY IN THE DECANTATION STAGE OF THE CONTACT WATER SYSTEM

DOI

10.5151/2594-3626-41330

Downloads

Baixar Artigo 5 Downloads

Resumo

O SISTEMA DE áGUA COM CONTATO é UTILIZADO NA ARCELORMITTAL RESENDE PARA REFRIGERAR EQUIPAMENTOS E PRODUTOS DURANTE A FABRICAçãO DE AçOS LONGOS. UMA OPERAçãO CRíTICA DESTE PROCESSO é A REMOçãO DE LAMA (CAREPA FINA) QUE OCORRE NO DECANTADOR LONGITUDINAL, QUE COM APLICAçãO DE POLíMERO, REDUZ A CONCENTRAçãO DE SóLIDOS SUSPENSOS, E óLEOS E GRAXAS. ESTES, APESAR DE SEPARADOS DA áGUA, AINDA PERMANECEM NO TANQUE E SEU ACúMULO INTERROMPE O SINCRONISMO DAS ETAPAS EM DIANTE. O DECANTADOR LONGITUDINAL POSSUI UMA PONTE RASPADORA QUE RETIRA óLEO DA SUPERFíCIE ATRAVéS DE UMA CANALETA E DIRECIONA A LAMA DEPOSITADA NO FUNDO PARA UMA CAVA QUE POSSUI UMA BOMBA SUBMERSA PARA RETIRAR A LAMA. O INSUCESSO DESTA BOMBA GERA ASSOREAMENTO E ACúMULO DE óLEO, IMPACTANDO A QUALIDADE DA áGUA. ENTãO FORAM REDIMENSIONADAS BOMBAS E TUBULAçõES GARANTINDO A PERFORMANCE NESTA POSIçãO CRíTICA E ALTAMENTE ABRASIVA. COM ISSO, OS RESULTADOS DE SóLIDOS SUSPENSOS E óLEOS E GRAXAS ENQUADRARAM, CONSEQUENTEMENTE A TAXA DE CORROSãO E DEPOSIçãO CAíRAM 65% E 96% RESPECTIVAMENTE. Já NO PROCESSO, OS IMPACTOS FORAM MAIORES, ZERANDO INTERRUPçõES DE CORRIDA DA ACIARIA, E REDUZINDO EM 54% O TEMPO DE INDISPONIBILIDADE DO LAMINADOR POR ENTUPIMENTOS DE BICOS

 

THE CONTACT WATER SYSTEM IS USED AT ARCELORMITTAL RESENDE TO COOL EQUIPMENT AND PRODUCTS DURING THE MANUFACTURE OF LONG STEEL. A CRITICAL OPERATION OF THIS PROCESS IS THE REMOVAL OF SLUDGE (FINE SCALE) THAT OCCURS IN THE LONGITUDINAL DECANTER, WHICH, WITH THE APPLICATION OF POLYMER, REDUCES THE CONCENTRATION OF SUSPENDED SOLIDS, OILS AND GREASES. THESE, DESPITE BEING SEPARATED FROM THE WATER, STILL REMAIN IN THE TANK AND THEIR ACCUMULATION INTERRUPTS THE SYNCHRONIZATION OF THE STAGES ONWARDS. THE LONGITUDINAL DECANTER HAS A SCRAPER BRIDGE THAT REMOVES OIL FROM THE SURFACE THROUGH A CHANNEL AND DIRECTS THE SLUDGE DEPOSITED AT THE BOTTOM TO A PIT THAT HAS A SUBMERGED PUMP TO REMOVE THE SLUDGE. THE FAILURE OF THIS PUMP GENERATES SILTING AND OIL ACCUMULATION, IMPACTING WATER QUALITY. PUMPS AND PIPES WERE THEN RESIZED, ENSURING PERFORMANCE IN THIS CRITICAL AND HIGHLY ABRASIVE POSITION. AS A RESULT, THE RESULTS FOR SUSPENDED SOLIDS AND OILS AND GREASES WERE IN LINE, CONSEQUENTLY THE CORROSION AND DEPOSITION RATES FELL BY 65% AND 96% RESPECTIVELY. IN THE PROCESS, THE IMPACTS WERE GREATER, ELIMINATING INTERRUPTIONS IN THE STEEL SHOP'S RUN, AND REDUCING THE ROLLING MILL'S UNAVAILABILITY TIME DUE TO NOZZLE CLOGGING BY 54%.

Palavras-chave

Água com Contato; Entupimento de Bicos; Sólidos Suspensos; Remoção de Lama.

Contact Water; Nozzle Clogging; Suspended Solids; Sludge Removal.

Como citar

AMORIM, CAROLINE MORGADO; SILVA, LEONARDO REIS DA; JUNIOR, FÁBIO FERNANDES MORAIS; SOUZA, PÚBLIO GALANE BRAZ E; SILVA, MICHELLE APARECIDA; SILVA, LEONARDO REIS DA; JUNIOR, FÁBIO FERNANDES MORAIS; SOUZA, PÚBLIO GALANE BRAZ E; SILVA, MICHELLE APARECIDA. ESTABILIDADE NA ETAPA DE DECANTAÇÃO DO SISTEMA DE ÁGUA COM CONTATO , p. 277-282. In: 43º Seminário de Energia, Utilidades e Transição Energética, São Paulo, Brasil, 2024.
ISSN: 2594-3626 , DOI 10.5151/2594-3626-41330