ESTUDO DA INFLUÊNCIA DA TEMPERATURA NA CORROSÃO SELETIVA DO AÇO UNS S31803 EM SOLUÇÃO 1M HCL

STUDY OF TEMPERATURE INFLUENCE ON SELECTIVE CORROSION OF UNS S31803 STEEL IN SOLUTION 1M HCL

DOI

10.5151/2594-4711-23381

Downloads

Baixar Artigo 126 Downloads

Resumo

O objetivo deste trabalho compreende o estudo da influência da temperatura de ensaio na corrosão seletiva do aço inoxidável dúplex UNS S31803 (SAF 2205) em solução 1M HCl. Para realização deste trabalho, amostras do aço em estudo foram solubilizadas por 4 horas a 1150°C, das quais foram preparados corpos-de-prova para a caracterização microestrutural, que foi realizada por meio de ataques metalográficos, análise por microscopia óptica e microscopia eletrônica de varredura. Para análise do comportamento eletroquímico do material, foram obtidas curvas de polarização potenciodinâmica nas temperaturas de 22, 30, 40, 50 e 60°C em solução 1M HCl. Nestas foi observada a existência de dois máximos de densidade de corrente, para todas as temperaturas estudadas, associados à dissolução ferrita e austenita que foram posteriormente comprovados por ensaios potenciostáticos realizados nos potenciais de dissolução de cada uma das fases. O estudo do comportamento eletroquímico mostra que potencial de equilíbrio da dissolução de ferrita é inferior à austenita, e a energia de ativação do processo de dissolução austenita é mais elevada em relação à ferrita indicando maior resistência à corrosão da austenita em relação à ferrita no meio em estudo.

 

This work comprises the study of temperature influence on selective corrosion of duplex stainless steel UNS S31803 (SAF2205) in 1M HCl. For this, samples were solution treated at 1150°C for 4 hours, which were prepared for microstructural characterization, performed by metallographic etching followed by optical microscopy and scanning electron microscopy. To analyze the electrochemical behavior of material, potentiodynamic polarization curves were raised at temperatures of 22, 30, 40, 50 and 60° C in 1M HCl. It was observed the presence of two maximum current density for all temperatures studied related to the dissolution ferrite and austenite, which were subsequently confirmed by potentiostatic tests carried out in dissolution potential of each phase. The electrochemical behavior shows that the ferrite dissolution potential is lower than austenite potential, and the activation energy of the austenite dissolution process is higher in relation to ferrite probably indicating improved corrosion resistance of the austenite to ferrite in the studied solution.

Palavras-chave

Aço inoxidável dúplex; Corrosão Seletiva; Temperatura de ensaio.

Aço inoxidável dúplex; Corrosão Seletiva; Temperatura de ensaio.

Como citar

Colli, Marcela Nunes; Santos, Daniella Caluscio dos; Morais, Luara da Costa. ESTUDO DA INFLUÊNCIA DA TEMPERATURA NA CORROSÃO SELETIVA DO AÇO UNS S31803 EM SOLUÇÃO 1M HCL , p. 356-366. In: 13º ENEMET - Encontro Nacional de Estudantes de Engenharia Metalúrgica, de Materiais e de Minas, São Paulo - Brasil, 2013.