Resumo

Este trabalho teve como objetivo avaliar o uso da tecnologia Controlled Memory (CM) para confecção de instrumentos endodônticos rotatórios de NiTi, comparando a flexibilidade e a resistência torcional de instrumentos Hyflex (HF) e Typhoon (TYP), que apresentam o efeito memória de forma, com os instrumentos ProTaper Universal F2 (PTU F2) e EndoWave (EW), fabricados com o fio de NiTi superelástico convencional. Os instrumentos avaliados possuíam calibre de ponta de 0,30 mm e conicidade de 6%, com exceção de PTU F2. As áreas médias das seções transversais a 3 mm da ponta (A3) foram determinadas em 10 instrumentos de cada tipo. Igual número de instrumentos foram testados em dobramento a 45° e em torção até a ruptura (ISO 3630-1). Os valores médios de A3 encontrados nos instrumentos HF, TYP, PTU F2 e EW foram, respectivamente, 0,084, 0,107, 0,122 e 0,082 mm2; os valores médios de momento de dobramento máximo: 0,327, 0,315, 1,1490 e 0,567 N.cm; e os valores médios de torque máximo: 1,047, 1,254, 1,400 e 1,111 N.cm. Verificou-se, portanto, que os instrumentos fabricados com a tecnologia CM apresentaram, quando comparados aos instrumentos com valores próximos de A3, maior flexibilidade (menor momento de dobramento máximo) e resistência torcional semelhante. Os resultados encontrados mostraram que a tecnologia CM permite a produção de instrumentos endodônticos mais flexíveis, o que é desejável do ponto de vista clínico, porém sem comprometer a sua resistência torcional.

 

This study aimed to evaluate the use of Controlled Memory (CM) technology for the manufacture of rotary endodontic NiTi instruments, comparing the flexibility and torsional resistance of Hyflex (HF) and Typhoon (TYP) instruments, which exhibit the shape memory effect, with instruments ProTaper Universal F2 (PTU F2) and EndoWave (EW), manufactured with conventional superelastic NiTi wire. The instruments evaluated possessed a 0.30 mm caliber tip and 6 % taper, except for PTU F2. The mean cross-sectional areas at 3 mm from the tip (A3) were determined in 10 sections of each instruments type. Equal number of instruments was tested in bending at 45° and in torsional (ISO 3630-1). The average values of A3 found for HF, TYP, PTU F2 and EW instruments were 0.084, 0.107, 0.122 and 0.082 mm2, respectively, while the average values of maximum bending moment were 0.327, 0.315, 1.1490 and 0.567 N.cm, and the mean values of maximum torque: 1.047, 1.254, 1.400 and 1.111 N.cm. These results showed that the CM technology allows the production of instruments which show, when compared instruments with similar values of A3, greater flexibility (lowest maximum bending moment) and similar torsional. The results obtained demonstrated that the CM technology enables the production of more flexible endodontic instruments, which is desirable from a clinical point of view, but without compromising their torsional strength.

Palavras-chave

Ligas NiTi; Efeito memória de forma; Instrumentos endodônticos; Flexibilidade; Resistência torcional

NiTi alloys; Shape memory effect; Endodontic instruments; Flexibility; Torsional strength