ISSN 2594-5300
53º Seminário de Aciaria, Fundição e Metalurgia de Não-Ferrosos — vol. 53, num.53 (2024)
Título
Autoria
DOI
Downloads
Resumo
A ACIARIA 2 DA USIMINAS OPERA COM DUAS MáQUINAS DE LINGOTAMENTO COM DOIS VEIOS CADA. UMA DIAGNOSE DO BICO SPRAY AR MISTO DO RESFRIAMENTO SECUNDáRIO EVIDENCIOU DESEMPENHO DO PERFIL DE DISTRIBUIçãO DE áGUA DE 50% E VARIABILIDADE NO COEFICIENTE DE TRANSFERêNCIA DE CALOR DE 38%. MEDIANTE A ISSO, O FORNECEDOR DE BICO SPRAY DESENVOLVEU UM NOVO PROJETO EM BANCADA QUE AUMENTOU A REGULARIDADE DO PERFIL DE DISTRIBUIçãO PARA 80% E REDUZIU A VARIABILIDADE NO COEFICIENTE DE TRANSFERêNCIA DE CALOR PARA MENOS DE 10%. POSTERIORMENTE REALIZOU-SE UM TESTE COMPARATIVO EM UM DOS VEIOS. O VEIO EXPERIêNCIA COM O NOVO PROJETO DE BICO SPRAY APRESENTOU MAIOR REGULARIDADE TéRMICA AO LONGO DA LARGURA DE PLACA E UMA TRANSIçãO TéRMICA ENTRE SEGMENTOS MAIS SUAVE E GRADATIVA. TAMBéM FOI CONSTATADO UM INCREMENTO NA QUALIDADE DE PLACA PELA REDUçãO DA INTENSIDADE DA ESPESSURA DA SEGREGAçãO CENTRAL EM ATé 0,50 MM, REDUçãO DA INTENSIDADE DO TAMANHO DE TRINCAS HORIZONTAIS EM 47% E REDUçãO DE FORMAçãO DE TRINCAS SUPERFICIAIS EM 12,5% EM AçO MéDIO CARBONO PERITéTICO ESCARFADO. O NOVO PROJETO DE BICO SPRAY GERA OPORTUNIDADE PARA O DESENVOLVIMENTO DE NOVOS PLANOS DE SPRAY E POTENCIALIZA O GANHO DE QUALIDADE PLACA.
THE STEELMAKING PLANT 2 OF USIMINAS OPERATES WITH TWO CASTING MACHINES WITH TWO STRANDS EACH. A DIAGNOSIS OF THE SECONDARY COOLING SPRAY AIR MIST NOZZLE SHOWED A WATER DISTRIBUTION PROFILE PERFORMANCE OF 50% AND VARIABILITY IN THE HEAT TRANSFER COEFFICIENT OF 38%. IN FRONT OF THIS, THE SPRAY NOZZLE SUPPLIER DEVELOPED A NEW BENCH DESIGN THAT INCREASED THE REGULARITY OF THE DISTRIBUTION PROFILE TO 80% AND REDUCED THE VARIABILITY IN THE HEAT TRANSFER COEFFICIENT TO LESS THAN 10%. SUBSEQUENTLY, A COMPARATIVE TEST WAS CARRIED OUT ON ONE OF THE STRANDS. THE EXPERIMENT STRAND WITH THE NEW SPRAY NOZZLE DESIGN SHOWED GREATER THERMAL REGULARITY ACROSS THE SLAB WIDTH AND A SMOOTHER AND MORE GRADUAL THERMAL TRANSITION BETWEEN SEGMENTS. AN INCREASE IN SLAB QUALITY WAS ALSO FOUND BY REDUCING THE INTENSITY OF THE CENTRAL SEGREGATION THICKNESS BY UP TO 0.50 MM, REDUCING THE INTENSITY OF THE SIZE OF HORIZONTAL CRACKS BY 47% AND REDUCING THE FORMATION OF SUPERFICIAL CRACKS BY 12.5% IN PERITECTIC MEDIUM CARBON STEEL SCARFED. THE NEW SPRAY NOZZLE DESIGN CREATES OPPORTUNITIES FOR THE DEVELOPMENT OF NEW SPRAY PLANS AND ENHANCES THE POTENTIAL FOR SLAB QUALITY IMPROVEMENT.
Palavras-chave
Lingotamento contínuo de placa; Resfriamento secundário; Bico spray ar misto; Qualidade de placas.
Continuous slab casting; Secondary cooling; Air mist spray nozzle; Steel slab quality.
Como citar
MENDONÇA, ALEXANDRE DE FREITAS GOMES DE;
FANTINI, LEANDRO VILAS BOAS;
JÚNIOR, HORMANDO LEOCÁDIO.
MELHORIA DE QUALIDADE DE PLACA PELO AUMENTO DE DESEMPENHO DO RESFRIAMENTO SECUNDÁRIO NO LINGOTAMENTO DA ACIARIA 2 DA USIMINAS IPATINGA
,
p. 461-473.
In: 53º Seminário de Aciaria, Fundição e Metalurgia de Não-Ferrosos,
São Paulo, Brasil,
2024.
ISSN: 2594-5300
, DOI 10.5151/2594-5300-41063