Anais do Seminário de Aciaria, Fundição e Metalurgia de Não-ferrosos


ISSN 2594-5300

40º Seminário de Aciaria vol. 40, num.40 (2009)


Título

OTIMIZAÇÃO DA TROCA A QUENTE DO FUNDO DO CONVERTEDOR MRP-L DE FORMA SEGURA

OPTIMIZATION OF HEAT EXCHANGE AT THE BOTTOM OF MRP-L CONVERSOR IN A SAFE WAY

DOI

10.5151/2594-5300-0003

Downloads

Baixar Artigo 153 Downloads

Resumo

O convertedor MRP-L, é um convertedor básico a oxigênio, que também utiliza a injeção de gases inerte (Ar/N2) através de cinco elementos porosos, localizados no fundo do vaso. Em função do maior desgaste da região dos plugues o fundo do convertedor MRP-L era trocado em até cinco vezes durante uma campanha refratária. No período de abril a maio de 2007, tivemos três ocorrências consecutivas de graves problemas com fundo do MRP-L (Vazamento de aço na interface do refratário do fundo intercambiável com a parte inferior do revestimento do vaso e queda de tijolos do fundo). Foi verificada uma ausência de massa refratária na região onde houve vazamento de metal. Desenvolveu-se então uma nova metodologia da troca do fundo do convertedor, com montagem de um sistema de injeção de uma nova massa refratária de magnésia, úmida, de pega a quente e ligada à resina, desenvolvida na Magnesita, especialmente para esta aplicação. Também foi modificado o formato dos tijolos que compõem o fundo do convertedor com usinagem de sistema macho e fêmea, garantindo, assim, um excelente encaixe dos mesmos, e eliminação dos riscos de deslocamento. Como resultado, o novo sistema garante a completa selagem da interface dos tijolos do fundo com os tijolos da lateral do convertedor, Além da melhor performance, foi reduzido em 20% o tempo necessário para a troca do fundo, também foi possível atingir um novo recorde de produção de corridas em uma única campanha refratária do forno de 6120 corridas.

 

The MRP-L conversor is a basic oxygen conversor which also uses an injection of inert gas (Ar/N2) through porous elements located at the bottom of the conversor. Due to the greater wear of the areas surrounding the plugs at the bottom of the conversor it was replaced up to five times during a refractory period. From April to May 2007 we had three consecutive incidents with serious problems at the bottom of the MRP-L (steel leaked at the interface between exchangeable bottom refractory and the lower coating of the vase and some bricks from the bottom fell). It was noticed the absence of refractory mortar in the area where the leaking occurred. A new methodology was developed to replace the conversor bottom. A new system was developed with the injection of magnesium refractory mortar , humid , which can used hot, using resin as binder. This product was developed by Magnesita specially for this application. The bricks that form the bottom of the conversor were also modified using machining male and female parts to ensure a perfect fitting to avoid risk of displacement. As a result the new system ensure a complete sealing of the interface between the bricks from the bottom and side of the conversor. On top of better performance , the replacement time of the bottom was reduced by 20%. Which allowed to reach a new record number of heats, 6120 , in an only refractory period.

Palavras-chave

Convertedor; MRP-L; Troca do fundo.

Conversor; MRP-L; Replacement of the bottom

Como citar

Campos, Adão Adelcio; Lana, Anderson Batista; Roldão, Antonio Marcos Bolba; Pagliosa, Carlos; Tomazio, Cleber Caetano; Cavalieri, Edilson Simões; Quintão, Hélcio de Araújo; Reis, Luiz Wander Tonelli; Júnior, João Domingos Guimarães de Athayde; Pinto, José Eustáquio; Ank, José Geraldo; Teixeira, Otávio Augusto da Cunha; Neves, João Cordeiro. OTIMIZAÇÃO DA TROCA A QUENTE DO FUNDO DO CONVERTEDOR MRP-L DE FORMA SEGURA , p. 22-35. In: 40º Seminário de Aciaria, São Paulo, 2009.
ISSN: 2594-5300 , DOI 10.5151/2594-5300-0003