REDUÇÃO DE CORROSÃO NA COIFA DOS CONVERTEDORES

REDUCTION OF CORROSION IN THE HOODS OF THE CONVERTERS

DOI

10.5151/2594-5300-40243

Downloads

Baixar Artigo 37 Downloads

Resumo

As coifas dos convertedores são responsáveis por captar e fazer o resfriamento primário do gás proveniente do processo de produção de aço. Por conta das altas temperaturas e altas taxas de transferência de calor envolvidas nesse processo, o equipamento precisa ter refrigeração adequada, a fim de evitar sobreaquecimento e/ou corrosão que leve a falhas e necessidade de paradas no processo produtivo. O presente trabalho visa apresentar a metodologia e os resultados obtidos após limpeza química e modificação no tratamento da água de resfriamento das coifas dos convertedores da ArcelorMittal Tubarão. O tratamento prévio utilizava um sequestrante de oxigênio e foi substituído por programa a base de nitrito. Os resultados mostraram que a limpeza química foi capaz de remover a camada de oxido que estava depositada nas tubulações, sem comprometer sua integridade. O uso do nitrito favoreceu a formação de uma camada passivante, além de reduzir as taxas de corrosão em mais de 75% e a concentração de ferro no sistema em 40%. Com o novo programa químico, a condição ideal do processo de refrigeração foi reestabelecida, reduzindo falhas e aumentando a confiabilidade do sistema.

 

The hoods of the converters are responsible for the capturing and the primary cooling of the gas coming from the steel production process. Due to the high temperatures and high rates of heat transfer involved in this process, the equipment needs an adequate cooling to avoid overheating and/or corrosion that can lead to failures and the need for stoppages in the production process. The present work aims to introduce the methodology and results obtained after chemical cleaning and modification in the treatment of cooling water of ArcelorMittal Tubarão converter hoods. The previous treatment used an oxygen scavenger and was replaced by a nitrite-based program. The results showed that chemical cleaning was able to remove the oxide layer that was deposited on the pipes, without compromising its integrity. The use of nitrite favored the formation of a passivating layer, in addition to reducing corrosion rates by more than 75% and the iron concentration in the system by 40%. After the new chemical program, the ideal condition of the refrigeration process was reestablished, reducing failures, and increasing system reliability.

Palavras-chave

cONVERTEDORES; SIDERURGIA, REFRIGERAÇÃO INDUSTRIAL, COIFAS DE CAPTAÇÃO

Converters; Steelmaking; Industrial Cooling; Fixed and Mobile Hoods

Como citar

Bonini, Lidia Petronio; Rosa, André; Bof, Cláudia; Silva, Christian; Adrian, Edgar; Araújo, Fábio. REDUÇÃO DE CORROSÃO NA COIFA DOS CONVERTEDORES , p. 293-306. In: 52º Seminário de Aciaria, Fundição e Metalurgia de Não-Ferrosos, São Paulo, 2023.
ISSN: 2594-5300 , DOI 10.5151/2594-5300-40243