Anais dos Seminário de Energia, Utilidades e Gases Industriais


ISSN 2594-3626

Título

REMOÇÃO DE FLUORETO EM EFLUENTE UTILIZANDO MÉTODO DE PRECIPITAÇÃO QUÍMICA COM DESCARTE DIRETO PARA CORPO HÍDRICO

EFFLUENT FLUORIDE REMOVAL USING CHEMICAL PRECIPITATION METHOD WITH DIRECT DISCHARGE TO WATER BODY

DOI

10.5151/2594-3626-33779

Downloads

Baixar Artigo 752 Downloads

Resumo

A regulação ambiental de processos industriais que geram efluentes contendo fluoretos é mundialmente restrita devido à alta toxicidade do íon. Na Ternium, a água de resfriamento recirculada no spray do Lingotamento Contínuo (WTP#2) dissolve parte do pó fluxante, resultando em concentrações de 20 a 30 mg/L de fluoreto. Para desenvolvimento do processo de tratamento de fluoreto que atendesse a legislação, mantendo no efluente tratado concentração de Fluoreto menor que 10mg/L e Alumínio menor que 3,0mg/L, foi realizada uma pesquisa utilizando um equipamento de Jar Teste convencional totalizando 165 ensaios. Os ensaios foram planejados segundo revisões bibliográficas descrevendo o método da precipitação química de fluoreto de cálcio, auxiliado por Cátions de Alumínio. Na conclusão da pesquisa, foi desenvolvida uma Rota Tecnológica para tratamento do efluente gerado na purga do sistema WTP#2 atendendo a legislação, atingindo uma remoção de 70% a 80% de Fluoreto. Ao final foi realizada uma etapa de otimização das dosagens, cujo resultado foi a redução do número de etapas de tratamento e uma redução na quantidade de produtos químicos utilizados, consequentemente reduzindo o custo de tratamento. A redução do custo de tratamento foi da ordem de 3 milhões de reais anuais, mantendo o efluente tratado com as concentrações dos contaminantes abaixo dos limites da regulação ambiental.

 

The environmental regulation of industrial processes that generate fluoride-containing effluents is globally restricted due to the high toxicity of the ion. At Ternium, recirculated cooling water in the Continuous Casting Spray (WTP # 2) dissolves part of the flowing powder, resulting in concentrations of 20 to 30 mg / L of fluoride. For the development of the fluoride treatment process that complied with the legislation, keeping in the effluent treated Fluoride concentration less than 10mg / L and Aluminum less than 3.0mg / L, a research was carried out using a conventional Jar Test equipment totaling 165 tests. The trials were planned according to literature reviews describing the method of chemical precipitation of calcium fluoride, aided by Aluminum Cations. At the conclusion of the research, a Technological Route was developed to treat the effluent generated in the purge of the WTP # 2 system fulfilling the legislation, reaching a removal of 70% to 80% of Fluoride. At the end, a dosage optimization step was carried out, which resulted in a reduction in the number of treatment steps and a reduction in the amount of chemicals used, thus reducing the cost of treatment. The reduction in treatment costs was of the order of 3 million reais annually, keeping the effluent treated with concentrations of contaminants below the limits of environmental regulation.

Palavras-chave

Tratamento de efluente; Precipitação; Fluoreto

Effluent Treatment; Precipitation; Fluoride

Como citar

Lana, Matheus Neves; Belezia, Alberto Vicente; Santos, Jocemir da Silva. REMOÇÃO DE FLUORETO EM EFLUENTE UTILIZANDO MÉTODO DE PRECIPITAÇÃO QUÍMICA COM DESCARTE DIRETO PARA CORPO HÍDRICO , p. 125-134. In: 40° Seminário de Balanços Energéticos Globais e Utilidades, São Paulo, 2019.
ISSN: 2594-3626 , DOI 10.5151/2594-3626-33779