Anais do Congresso Anual da ABM


ISSN 2594-5327

74º Congresso Anual da ABM vol. 74, num.74 (2019)


Título

TÉCNICAS ELETROQUÍMICAS APLICADAS NA COMPARAÇÃO DA RESISTÊNCIA À CORROSÃO DE LIGAS BIOMÉDICAS

ELECTROCHEMICAL TECHNIQUES APPLIED FOR THE COMPARISON OF RESISTANCE TO CORROSION OF BIOMEDICAL ALLOYS

DOI

10.5151/2594-5327-33656

Downloads

Baixar Artigo 265 Downloads

Resumo

Diferentes materiais metálicos tem sido utilizados em aplicações biomédicas, dentre estes destacam-se os aços inoxidáveis, as ligas de cromo-cobalto e o titânio e suas ligas. Esses materiais possuem alta resistência mecânica, biocompatibilidade e alta resistência à corrosão. Essa alta resistência à corrosão está relacionada a capacidade destas ligas formarem juntamente com o oxigênio um filme passivo protetor em sua superfície. Esse filme protetor pode ser rompido na presença de alguns íons como fluoretos e cloretos. Este trabalho visou elucidar as propriedades de resistência à corrosão dessas ligas e mostrar por meio de ensaios eletroquímicos a resistência à corrosão de três ligas utilizadas para aplicação biomédica. As três ligas estudadas foram liga de CrCoMo, Ti CP e Ti ECAP. As técnicas eletroquímicas utilizadas foram polarização potenciodinâmica anódica e polarização potenciostática. Os resultados dessas análises mostraram que as três ligas estudadas possuem alta resistência à corrosão e são passivas. As ligas que apresentaram maior resistência à corrosão foram as ligas de titânio. Não foi observado diferença significativa na resistência entre o Ti CP e o Ti ECAP, a corrente apresentada por essas ligas foram muito próximas.

 

Different metallic materials are used for biomedical applications such as stainless steels, chromium-cobalt alloys and titanium and its alloys. These materials have high mechanical strength, biocompatibility and high corrosion resistance. This high corrosion resistance is related to the ability of these alloys to form a passive protective film on their surface. This protective film can be disrupted in the presence of some ions such as fluorides and chlorides. This work aimed to elucidate the corrosion resistance properties of these alloys and to show through electrochemical tests the corrosion resistance of three alloys used for biomedical application. The three alloys studied were CrCoMo, Ti CP and Ti ECAP alloys. The electrochemical techniques used were anodic potentiodynamic polarization and potentiostatic polarization. The results of these analyzes showed that the three alloys studied have high resistance to corrosion and are passive. The alloy with the highest corrosion resistance was titanium alloys. No significant difference in strength was observed between Ti CP and Ti ECAP, the current presented by these alloys was very near.

Palavras-chave

corrosão; filme passivo; ligas biomédicas; Biocompatibilidade.

Corrosion; Passive film; biomedical alloys; biocompatibility

Como citar

Soares, Francielly Moura de Souza; Santana, Ana Isabel de Carvalho; Santos, Emília Monteiro dos; Santos, Luíza Braga Ferreira dos; Coimbra, Maria Elisa Rodrigues; Gomes, Paula Anastácia Cairo de Moraes; Elias, Carlos Nelson. TÉCNICAS ELETROQUÍMICAS APLICADAS NA COMPARAÇÃO DA RESISTÊNCIA À CORROSÃO DE LIGAS BIOMÉDICAS , p. 2313-2320. In: 74º Congresso Anual da ABM, São Paulo, 2019.
ISSN: 2594-5327 , DOI 10.5151/2594-5327-33656