ISSN 2594-5327
49º Congresso anual — Vol. 49, Num. 1 (1994)
Título
Autoria
DOI
Downloads
Resumo
An ultrasonic method for determining the degree of planarity of an inner surface, inaccessible to a mechanical instrument, with an accuracy better than 20 microns, is presented. An adapted pulse echo method is described. A comparison between the ultrasonic and the mechanical measurements, made on a specially prepared laboratory sample, yielded a very good agreement, well within the required accuracy. Some discrepancies out of this range are observed and discussed. Examples of actual measurements are given.
Palavras-chave
ultrasonic testing, planarity measurement, inaccessible surface, pulse echo method, nondestructive testing
Como citar
Zilber, Raphael; Shilo, Klara.
Accurate Measurement of the Planarity of an Inaccessible Surface by Means of a Pulse Echo Ultrasonic Method,
p. 7-12.
In: 49º Congresso anual,
Rio de Janeiro, Brasil,
1994.
ISSN: 2594-5327, DOI 10.5151/2594-5327-49v1-07-12