Anais do Congresso Anual da ABM


ISSN 2594-5327

Título

CARACTERIZAÇÃO DE RESÍDUOS PARTICULADOS RESULTANTES DE ENSAIOS DE “FRETTING-CORROSION” EM IMPLANTES CIRÚRGICOS

CHARACTERIZATION OF PARTICULATE RESIDUES RESULTING FROM FRETTING CORROSION TESTS ON SURGICAL IMPLANTS

DOI

10.5151/2594-5327-21270

Downloads

Baixar Artigo 217 Downloads

Resumo

O uso de próteses modulares para artroplastia total de quadril apresenta muitas vantagens, porém as interfaces modulares são submetidas a micromovimentos que podem resultar em atrito e em corrosão por atrito, considerando os fluidos corpóreos. A liberação de produtos de corrosão e de resíduos particulados pode estimular reações biológicas adversas, assim como conduzir a desgaste acelerado na interface de articulação. Deste modo os métodos para avaliar a estabilidade mecânica e a resistência à corrosão por atrito das interfaces modulares são essenciais. Técnicas como microscopia ótica, microscopia eletrônica de varredura (MEV), ensaios de fretting-corrosion e fluorescência de raios X foram utilizadas para caracterizar resíduos particulados resultantes de ensaios de fretting-corrosion em implantes cirúrgicos. Os resultados obtidos neste estudo permitiram a caracterização da morfologia e demais características dos resíduos gerados por fretting-corrosion em implantes cirúrgicos, como a composição química dos resíduos. Resultados experimentais preliminares indicam que os resíduos são oriundos do contato da cabeça da prótese com a solução salina: corrosão preferencial no interior da cabeça.

 

The use of modular prostheses for total hip arthroplasty presents many advantages, but they are subjected to micromovements which can result in fretting and fretting-corrosion, dute to the body fluids. The release of corrosion products and particulate residues can stimulate adverse biological reactions and lead to rapid wear in the articulated interface. Therefore methods for evaluating mechanical stability and fretting corrosion resistance in the modular interfaces are essential. Techniques such as optical microscopy, scanning electron microscopy (SEM), fretting corrosion tests and X ray fluorescence were used to characterize particulate residues resulting from fretting corrosion tests in surgical implants. The results thus obtained allowed the characterization of the morphology and other characteristics of particulate residues generated by fretting corrosion in surgical implants, such as the chemical composition of the residues. Preliminary results indicate that these residues are originated in the contact between the prosthesis head and the saline solution: preferential corrosion inside the head.

Palavras-chave

Fretting-corrosion; Implantes; Microscopia.

Fretting-corrosion; Implants; Microscopy.

Como citar

Caminha, Iêda Maria Vieira; Barbosa, Cássio; Abud, Ibrahim de Cerqueira; Nascimento, Jôneo Lopes do; Barros, Tatiana Silva. CARACTERIZAÇÃO DE RESÍDUOS PARTICULADOS RESULTANTES DE ENSAIOS DE “FRETTING-CORROSION” EM IMPLANTES CIRÚRGICOS , p. 2413-2421. In: 67º Congresso da ABM - Internacional / 12º ENEMET - Encontro Nacional de Estudantes de Engenharia Metalúrgica, de Materiais e de Minas, Rio de Jabeiro, 2012.
ISSN: 2594-5327 , DOI 10.5151/2594-5327-21270