COMPARISON OF X-RAY FLUORESCENCE TECHNIQUES BY FUSED GLASS DISCS AND INDUCTIVELY COUPLED PLASMA (ICP) FOR CHEMICAL ANALYSIS OF DRILL HOLE SAMPLES

COMPARISON OF X-RAY FLUORESCENCE TECHNIQUES BY FUSED GLASS DISCS AND INDUCTIVELY COUPLED PLASMA (ICP) FOR CHEMICAL ANALYSIS OF DRILL HOLE SAMPLES

DOI

10.5151/2594-357x-0006

Downloads

Baixar Artigo 78 Downloads

Resumo

A possível existência de vício e diferenças de precisão entre as técnicas de Fluorescência de Raios-X por pastilha fundida e Plasma (ICP) para análise química de SiO2, P, Al2O3, Mn, CaO, MgO e TiO2 em amostras de furos de sondagem foi investigada. Amostras pulverizadas idênticas foram analisadas num programa interlaboratorial por laboratórios que utilizam RX e Plasma. Os dados gerados foram analisados em gráficos 1:1, Teste-t de Student e pela aplicação de normas ISO para cálculo da precisão e vício. Não existe tendência significativa para nenhum dos elementos quando se observa o comportamento dos dados para a faixa analítica inteira. Entretanto, para alguns elementos diferenças estatisticamente significativas foram observadas, para a média e/ou precisão Essas diferenças foram avaliadas tendo-se como referência as normas ISO pertinentes e também pela equipe responsável pelo banco de dados geológico para a aceitação dos resultados analíticos.

 

The possible existence of bias and precision differences between the techniques of X-ray Fluorescence by fused glass discs and Plasma (ICP) for the chemical analysis of SiO2, P, Al2O3, Mn, CaO, MgO and TiO2 in drill hole samples has been investigated. Identical pulverized samples were analyzed in an interlaboratory program by laboratories that use X-ray and Plasma. The data generated were analyzed in graphs 1:1, Student Test-t and by applying ISO standards for precision and bias calculation. There is no meaningful trend toward any of the elements when data behavior is observed for the entire analytical range. However, for some elements, statistically meaningful differences have been observed for the average and/or precision. These differences were appraised using as a reference the pertinent ISO standards and also by the team responsible for the geological database for the acceptance of analytical results.

Palavras-chave

Furos de sondagem; Plasma; Raios-X.

Drill hole; Plasma; X-ray

Como citar

Gomes, Mário Alzamora. COMPARISON OF X-RAY FLUORESCENCE TECHNIQUES BY FUSED GLASS DISCS AND INDUCTIVELY COUPLED PLASMA (ICP) FOR CHEMICAL ANALYSIS OF DRILL HOLE SAMPLES , p. 48-56. In: 38º Seminário de Redução de Minério de Ferro e Matérias-primas e 9º Simpósio Brasileiro de Minério de Ferro, São Luís - MA, 2008.
ISSN: 2594-357X , DOI 10.5151/2594-357x-0006