Anais do Congresso Anual da ABM


ISSN 2594-5327

60º Congresso Anual da ABM vol. 60, num.60 (2005)


Título

DETERMINAÇÃO DO GRAU DE SENSITIZAÇÃO DA LIGA INCONEL 600 MA SUBMETIDO A DIFERENTES TRATAMENTOS TÉRMICOS

DETERMINATION OF SENSITIZATION DEGREE OF ALLOY 600 MA SUBMITTED TO DIFFERENT THERMAL TREATMENTS

DOI

10.5151/2594-5327-0050

Downloads

Baixar Artigo 37 Downloads

Resumo

O Inconel 600 MA é empregado em componentes do circuito primário de refrigeração do reator nuclear de Angra I em ambiente aquoso sob alta temperatura e pressão. Nestas condições esta liga é susceptível à corrosão sob tensão (CST) e a sensitização é extremamente importante nesse processo. Este trabalho tem por objetivo avaliar o grau de sensitização da liga Inconel 600 MA submetida à diferentes tratamentos térmicos, utilizando-se a técnica de DL-EPR (double loop eletrochemical potentiokinetic reactivation method) devidamente adaptada a este material. O comportamento das diversas amostras em relação à corrosão foi avaliado pela técnica eletroquímica de polarização anódica potenciodinâmica, que determina as características das regiões ativa e passiva para uma dada liga. O eletrólito utilizado neste trabalho (0,1 M H2SO4 + 0,001 M KSCN) mostrou-se o mais adequado segundo a análise microestrutural. Os valores obtidos da razão Ir /Ia, que expressa o grau de sensitização das amostras estudadas, foram coerentes com a análise microestrutural, o mapeamento de raios-X por microsonda eletrônica, os ensaios de polarização anódica e com dados de literatura. Isto indica que a técnica DL-EPR pode ser utilizada para determinar o grau de sensitização da liga Inconel 600 MA.

 

Mill annealed (MA) nickel alloy 600 is used in structural components of primary coolant of Angra 1 nuclear power plant, where it is subject to a high temperature and pressure aqueous environment. In these conditions it is reported that the alloy is susceptible to stress corrosion cracking and can also be susceptible to intergranular attack due to sensitization phenomenon. The objective of this paper is to evaluate the degree of sensitization of alloy 600 MA submitted to different thermal treatments, by means of DL-EPR (double loop electrochemical potentiokinetic reactivation) technique duly adapted to this material. The corrosion behavior of the samples was investigated by the potentiodynamic anodic polarization technique, that is used to determine the active/passive characteristics of a given metal-solution system. The electrolyte used in this work (0,1 M H2SO4 + 0,001 M KSC) was the most appropriate according to microstructural analysis. The relation Ir /Ia of the samples evaluated, that expresses the degree of sensitization, were consistent with microstructural analysis, results of the composition mapping by WDX and the potentiodynamic anodic polarization techniques along with literature data. These results indicate that the DL-EPR could be used to determine the degree of sensitization of alloy 600 MA.

Palavras-chave

Inconel 600 MA; Grau de sensitização; Corrosão sob tensão; Técnica de reativação potenciocinética.

Alloy 600 MA, degree of sensitization, stress corrosion cracking, potentiokinetic reactivation technique.

Como citar

Lourenço, Luciana Iglésias; Matias, Adalberto; Moreira, Marcílio Soares; Neves, Célia de Figueiredo Cordeiro; Campos, Wagner Reis da Costa. DETERMINAÇÃO DO GRAU DE SENSITIZAÇÃO DA LIGA INCONEL 600 MA SUBMETIDO A DIFERENTES TRATAMENTOS TÉRMICOS , p. 491-500. In: 60º Congresso Anual da ABM, Belo Horizonte, 2005.
ISSN: 2594-5327 , DOI 10.5151/2594-5327-0050