Anais do Congresso Anual da ABM


ISSN 2594-5327

70º Congresso Anual da ABM vol. 70, num.70 (2015)


Título

EVIDÊNCIA DA PRECIPITAÇÃO DA FASE Z NO AÇO INOXIDÁVEL AUSTENÍTICO ALTO NITROGÊNIO ASTM F 1586 POR RELAXAÇÃO DE TENSÃO

EVIDENCE OF PRECIPITATION Z-PHASE IN STAINLESS STEEL AUSTENITIC HIGH NITROGEN ASTM F 1586 BY STRESS RELAXATION

DOI

10.5151/1516-392X-26329

Downloads

Baixar Artigo 270 Downloads

Resumo

Usando os testes de torção a quente isotérmico contínuo e relaxação de tensão determinou-se as curvas de escoamento plástico e de relaxação de tensão, juntamente com a evolução mecânica e microestrutural do aço inoxidável austenítico ISO 5832-9 segundo as condições de deformação expressa pelo parâmetro de Zener-Hollomon (Z). Equações constitutivas foram usadas para avaliar e prever o amaciamento dinâmico. Verificou-se que os níveis de tensões são elevados com alto valor de energia de ativação aparente e descolamento da deformação crítica e de pico para as condições de alto Z. A tensão crítica encontra-se muito próxima do pico de tensão produzindo um retardo no início da recristalização dinâmica. Além do pico vê-se que o estado estacionário de tensões é alcançado para grandes deformações evidenciando um atraso no amaciamento dinâmico. Este comportamento é consequência da moderada valor de energia de falha de empilhamento (EFE), átomos de soluto em solução sólida (Nb, N, Mo) e presença de partículas de precipitados da fase Z (NbCrN) reduzindo a mobilidade das discordâncias e contornos de grãos retardando a cinética de recristalização.

 

Using the hot torsion testing isothermal and continuous stress relaxation determined whether the plastic flow curves and stress relaxation, together with the mechanical and microstructural evolution of austenitic stainless steel ASTM F 1586 according to strain conditions expressed by the parameter Zener-Hollomon (Z). Constitutive equations were used to evaluate and predict the dynamic softening. It was found that the stress levels are high with high value of the apparent activation energy, critical strain and displacement of the peak for Z high. Conditions of high critical stress are very close to the peak stress producing a delayed start the dynamic recrystallization (DRX). Besides it is seen that peak steady state stress is reached for large strains showing a dynamic delay in softening. This behavior is a consequence of moderate stacking fault energy (SFE) value, solute atoms in the solid solution (Nb, C, Mo) and the presence of precipitated particles of the Z-phase stage (NbCrN) reducing the movement of dislocations and contours grain retarding recrystallization kinetics.

Palavras-chave

Implantes, Amaciamento, Precipitação dinâmica, Fase Z

Implants, Softening, Dynamic precipitation, Phase-Z

Como citar

Silva, Eden Santos; Rocha, Ingrid Pinheiro; Boas, Debora Cristina Coltinho Vilas; Reis, Gedeon Silva; Balancin, Oscar. EVIDÊNCIA DA PRECIPITAÇÃO DA FASE Z NO AÇO INOXIDÁVEL AUSTENÍTICO ALTO NITROGÊNIO ASTM F 1586 POR RELAXAÇÃO DE TENSÃO , p. 488-501. In: 70º Congresso Anual da ABM, Rio de Janeiro, 2015.
ISSN: 2594-5327 , DOI 10.5151/1516-392X-26329