Proceedings of ABM Annual Congress


ISSN 2594-5327

62º Congresso anual da ABM vol. 62, num.62 (2007)


Title

AVALIAÇÃO DA CORROSÃO DE ARMADURA EM CONCRETO DE UMA PONTE DE 50 ANOS SOBRE O RIO TODOS OS SANTOS EM MINAS GERAIS

CORROSION OF THE REINFORCED CONCRETE OF A 50 YEARS OLD BRIDGE OVER THE TODOS OS SANTOS RIVER IN MINAS GERAIS

DOI

10.5151/2594-5327-0032

Downloads

Abstract

Em 2002, foi iniciado um diagnóstico do atual estado de conservação de uma ponte, construída há 50 anos em Teófilo Ottoni, Minas Gerais, visando sua restauração. A ponte tem apoio central em pilares cujas fundações localizam-se no leito do Rio Todos os Santos. A ponte não apresentou recalques verticais de fundação dos pilares centrais significativos, entretanto apresenta intenso processo de corrosão das armaduras das longarinas laterais, nas seções transversais situadas aproximadamente no meio dos vãos, bem como de trechos da laje e de algumas transversinas. O objetivo deste trabalho é estudar a corrosão das armaduras da ponte, realizando-se a caracterização do aço e dos produtos de corrosão por meio de análise química e metalográfica, difração de raios-X e microscopia eletrônica de varredura acoplada a espectroscopia de energia dispersiva. O aço estrutural é ferrítico, com 0,092 % em peso de carbono, e tamanho de grão entre 7 e 8 ASTM. A análise semi- quantitativa de composição, usando-se espectroscopia de energia dispersiva, da superfície do aço corroído identificou a presença de oxigênio, enxofre e ferro no produto de corrosão. As fases identificadas no produto da corrosão, usando-se difração de raios-X, foram magnetita, Fe3O4, e goetita, FeO(OH).

 

The bridge studied in this work is localized at Getúlio Vargas Avenue,Teófilo Ottoni, Minas Gerais. The bridge was built 50 years ago and shows severe corrosion. A diagnosis of the corrosion process installed in the bridge was initiated in 2002 as the first stage for the complete restoration of the bridge. The bridge has a central support in pillars, which foundation is in the riverbed. The bridge did not show vertical upset of foundation of central pillars, but showed an intense rebar corrosion of lateral longitudinal girders, of transversal sections in the middle of bridge spans, and of the concrete slab and some transversal girders. The aim of this work is to study the rebar corrosion of the 50 years old bridge by using chemical, and metallographic analysis, X-ray diffraction, and scanning electron microscopy with energy dispersive spectroscopy. The steel corroded was ferritic, with 0.092 % wt/wt carbon. The grain size of the steel was between 7 and 8 ASTM. Energy dispersive spectroscopy analysis showed the presence of oxygen, sodium, aluminum, silicon, calcium, and iron on the steel surface, and the presence of oxygen, sulfur, and iron on the surface of corrosion product. The phases identified in the corrosion product were magnetite, Fe3O4, and e gothite, FeO(OH).

Keywords

Corrosão de armadura; Ponte; Goetita.

Rebar corrosion; Bridge; Gothite

How to refer

Costa, M.G.; Carvalho, M.X.S.; Chagas, R.R.R.; Leite, C.M.; Bergo, R.S.; Andrade, S.S.; Modesto, M.; Paula, F.A.; Paula, F.Amorim de; C.Lins, V.F.. AVALIAÇÃO DA CORROSÃO DE ARMADURA EM CONCRETO DE UMA PONTE DE 50 ANOS SOBRE O RIO TODOS OS SANTOS EM MINAS GERAIS , p. 288-296. In: 62º Congresso anual da ABM, Vitória, 2007.
ISSN: 2594-5327 , DOI 10.5151/2594-5327-0032