Proceedings of ABM Annual Congress


ISSN 2594-5327

68º Congresso da ABM vol. 68, num.68 (2013)


Title

CINÉTICA DE AUSTENITIZAÇÃO INTERCRÍTICA DE UM FERRO NODULAR LIGADO

THE KINETICS OF INTERCRITICAL AUSTENITIZING IN AN ALLOYED DUCTILE IRON

DOI

10.5151/2594-5327-23454

Downloads

Abstract

A classe 750-500-11 da norma ASTM A897-2006 dos ferros nodulares austemperados envolve austenitização a partir da zona crítica. A literatura apresenta valores bastante dispersos quanto ao tempo de austenitização na zona crítica, havendo relatos desde 20 minutos até 5 horas de manutenção no patamar. O presente trabalho visa o estudo da cinética de austenitização intercrítica de um ferro fundido nodular ligado com Cu, Ni, Mn e Mo com matrizes inicialmente ferríticas e perlíticas. Amostras foram austenitizadas a 795°C por 2; 4; 6, 8 e 12h em forno convencional seguidas de têmpera em água a temperatura ambiente. Análises de microdureza da martensita (antiga austenita) indicaram que para amostras inicialmente ferríticas nesta temperatura de austenitização intercrítica o sistema alcança o equilíbrio após 8h de tratamento. As microestruturas apresentaram homogeneidade e aproximadamente 60% de martensita, quando em equilíbrio, indicando que o material encontrava-se dentro da zona crítica.

 

The grade 750-500-11 of the standard ASTM A897-2006 about austempered ductile iron involves isothermal treatment in intercritical range. The literature is very scattered about the intercritical austenitizing time, with reports from 20 minutes to 5 hours. This work aims to study the kinetics of intercritical austenitizing a ductile iron alloyed with Cu, Ni, Mn and Mo ferritic and pearlitic matrices initially. Samples were austenitized at 795°C for 2; 4; 6, 8 and 12 hours in a conventional furnace followed by quenching in water at room temperature. Microhardness analysis of martensite (old austenite) showed that for this samples initially ferritc austenitized at 795°C the system reaches equilibrium after 8 hours of treatment. The samples showed homogeneity and large amounts of martensite (around 60%), in equilibrium, it means that the material was in the intercritical range.

Keywords

Zona crítica; ADI dual; Austenitização intercrítica.

Intercritical range; ADI dual; Intercritical austenitizing.

How to refer

Lopes, Clarissa Lussoli; Bernardini, Pedro Amedeo Nannetti; Guesser, Wilson Luiz. CINÉTICA DE AUSTENITIZAÇÃO INTERCRÍTICA DE UM FERRO NODULAR LIGADO , p. 3510-3519. In: 68º Congresso da ABM, São Paulo, 2013.
ISSN: 2594-5327 , DOI 10.5151/2594-5327-23454