Abstract

O apagão ocorrido em 15 de agosto de 2023 evidenciou a necessidade de ampliar a observabilidade e a capacidade de análise dinâmica do Sistema Interligado Nacional (SIN), especialmente diante da crescente participação das fontes renováveis baseadas em inversores. Em resposta a esse evento, o Operador Nacional do Sistema (ONS) estabeleceu novos requisitos técnicos para a obtenção da Declaração de Atendimento aos Procedimentos de Rede (DAPR-D), incorporando melhorias nos Registradores Digitais de Perturbações (RDPs) e a adoção de Medições Fasoriais Sincronizadas (PMUs). Este artigo apresenta os principais requisitos regulatórios associados a esse processo, detalhando as etapas e aprofundando no processo da campanha de corrente. Também são discutidas as novas exigências para disparo de oscilografias por grandezas analógicas e o monitoramento dos modos de suporte de tensão dos inversores durante eventos de subtensão e sobretensão (LVRT/HVRT). Por meio de estudos de caso em empreendimentos fotovoltaicos de grande porte, são apresentados os desafios de implementação e os benefícios obtidos com o aumento da observabilidade do sistema.

 

The blackout on August 15, 2023, highlighted the need to enhance the observability and dynamic analysis capabilities of the Brazilian National Interconnected System (SIN), particularly in light of the increasing share of inverter-based renewable energy sources. In response to this event, the National System Operator (ONS) established new technical requirements for obtaining the Declaration of Compliance with Grid Procedures (DAPR-D), incorporating improvements to Digital Disturbance Recorders (DDRs) and the implementation of Synchronized Phasor Measurements (PMUs). This paper presents the main regulatory requirements associated with this process, detailing the implementation stages and providing an in-depth discussion of the current injection testing campaign. It also addresses the new requirements for oscillography triggering based on analog quantities variations, as well as the monitoring of inverter voltage support modes during under-voltage and over-voltage events (LVRT/HVRT). Through case studies in large-scale photovoltaic plants, the challenges associated with implementation and the benefits achieved through increased system observability are presented.

Keywords

Sistema Interligado Nacional (SIN), Fontes Renováveis Baseadas em Inversores (IBR), Registrador Digital de Perturbações (RDP), Medições Fasoriais Sincronizadas (PMU)

Brazilian National Interconnected System (SIN), Inverter-Based Resources (IBR), Digital Fault Recorder (DFR), Phasor Measurement Unit (PMU)

How to cite

Soares, Paulo Henrique Vieira; Catarino, Vitor Hugo Oliveira. Como medições fasoriais sincronizadas e registradores digitais de pertubação Estão Redefinindo a Integração das Fontes Renováveis ao Sistema interligado Nacional, p. 206-217. In: 45th Seminar on Energy, Utilities and Energy Transition, São Paulo, SP - Brasil, 2026.