O presente trabalho consiste por meio de ensaio mecânico de fadiga com torção em próteses de quadril referente à norma NBR ISO 7206, em analisar a deformação ocorrida nos corpos de prova de liga de aço inoxidável (Cr-Ni-Mo) de dois fabricantes nacionais distintos. Os equipamentos utilizados para aplicação desses ensaios foram duas máquinas universais de ensaio mecânico: INSTRON 8872 e INSTRON ElectroPuls E3000; e dispositivos adequados ao ensaio. Na sua caracterização utilizaram-se parâmetros de referências normativas (NBR ISO 7206: parte 4 e 8): carga máxima aplicada de 2300N, carga mínima aplicada 300N, total de ciclos: 5x106 e freqüência de 10 Hz. Com base no ensaio com as características acima, foi criado um gráfico posição do pistão (mm) X número total de ciclos com a deformação inicial e mais de 50 pontos, esses retirados da média de cada 100000 ciclos realizados, e assim estudou-se a deformação das próteses de quadril por meio comparativo, que serão apresentados no trabalho.

 

The present work is through mechanical fatigue test with torsion in hip prosthesis on the standard NBR ISO 7206, to analyze the deformation occurred in the specimens of stainless steel (Cr-Ni-Mo) two distinct national manufacturers. Equipment used for application of these tests was two universal machines for mechanical tests: INSTRON 8872 and INSTRON ElectroPuls E3000; and devices appropriate for testing. In its characterization parameters were used for normative references (NBR ISO 7206: parts 4 e 8): load maximum applied 2300N, load minimum applied 300N, total cycles: 5x106 e frequency 10 Hz. Based on the test with the above features, created a chart position of the piston (mm) X total number of cycles with initial deflection and more than 50 points, those taken from the average of every 100,000 cycles performed, and so we studied the deformation of the hip prosthesis by comparing, will be presented in the work.

Keywords

Fadiga; Deformação; Prótese.

Fatigue; Deformation; Prosthesis.

How to refer

Keide, Hugo; Perdigão, Paulo; Souza, Juliana Soares de; Mendonça, Rodrigo; Caminha, Ieda Maria; Filho, Walter Ferreira. ENSAIO MECÂNICO DE FADIGA EM PRÓTESE DE QUADRIL: ANÁLISE COMPARATIVA DA DEFORMAÇÃO1 , p. 700-708. In: 65º Congresso ABM, Rio de Janeiro, 2010.
ISSN: 2594-5327 , DOI 10.5151/2594-5327-16113