Powered by Blucher Proceedings

Proceedings of the Seminar on Steelmaking, Casting and Non-Ferrous Metallurgy


ISSN 2594-5300

Title

EOF INJECTORS CONFIGURATION TO REDUCE MIXING TIME MEASURE VIA CONDUCTIVIMETRY AND LUCIMETRY

EOF INJECTORS CONFIGURATION TO REDUCE MIXING TIME MEASURE VIA CONDUCTIVIMETRY AND LUCIMETRY

Authorship

DOI

10.5151/2594-5300-42080

Downloads

0 Downloads

Abstract

EOF is a 100% national reactor equipped with a scrap preheater and 4 oxygen injection points. This article investigates two parameters of these oxygen injectors through a physical model on a 1/6 scale of the industrial reactor. It also brings the novelty of measuring the mixing time using two techniques simultaneously: conductivity meter and lux meter. The results show that higher flow rates and shorter bath launch distances lead to shorter mixing times. It also presents a distinction between the readings by the two techniques depending on the reading method versus test conditions. Finally, it allows evaluating the best configuration that minimizes the passage of material through the slag port.

 

EOF IS A 100% NATIONAL REACTOR EQUIPPED WITH A SCRAP PREHEATER AND 4 OXYGEN INJECTION POINTS. THIS ARTICLE INVESTIGATES TWO PARAMETERS OF THESE OXYGEN INJECTORS THROUGH A PHYSICAL MODEL ON A 1/6 SCALE OF THE INDUSTRIAL REACTOR. IT ALSO BRINGS THE NOVELTY OF MEASURING THE MIXING TIME USING TWO TECHNIQUES SIMULTANEOUSLY: CONDUCTIVITY METER AND LUX METER. THE RESULTS SHOW THAT HIGHER FLOW RATES AND SHORTER BATH LAUNCH DISTANCES LEAD TO SHORTER MIXING TIMES. IT ALSO PRESENTS A DISTINCTION BETWEEN THE READINGS BY THE TWO TECHNIQUES DEPENDING ON THE READING METHOD VERSUS TEST CONDITIONS. FINALLY, IT ALLOWS EVALUATING THE BEST CONFIGURATION THAT MINIMIZES THE PASSAGE OF MATERIAL THROUGH THE SLAG PORT.

Keywords

Mixing Time, EOF, injector, yield, conductivimetry, lucimetry

Mixing Time, EOF, injector, yield, conductivimetry, lucimetry

How to cite

Cardoso, Rafaela; Junior, Carlos Silame; Lemos, Leandro Rocha; Maia, Breno Totti; Nogueira, Caio Diniz; Araujo, Ely. EOF INJECTORS CONFIGURATION TO REDUCE MIXING TIME MEASURE VIA CONDUCTIVIMETRY AND LUCIMETRY, p. 282-292. In: 54rd Seminar on Steelmaking, Casting and Non-Ferrous Metallurgy, São Paulo, Brasil, 2025.
ISSN: 2594-5300, DOI 10.5151/2594-5300-42080