Proceedings of ABM Annual Congress


ISSN 2594-5327

65º Congresso ABM vol. 65, num.65 (2010)


Title

ESCÓRIA DE ACIARIA ELÉTRICA MICRONIZADA: DESEMPENHO DE ARGAMASSAS FRENTE AO ATAQUE ÍONS CLORETO

MICRONIZED ELECTRICAL STEEL MAKING SLAG: PERFORMANCE OF MORTAR AGAINST ATTACK OF CHLORIDE IONS

DOI

10.5151/2594-5327-16476

Downloads

Abstract

A pesquisa teve como objetivo, avaliar o desempenho de argamassas produzidas com misturas de cimento Portland (CP V ARI RS) e escória de aciaria elétrica micronizada, frente ao ataque íons cloreto. A relevância do estudo está fundamentada na necessidade de se avaliar a durabilidade de argamassas / concretos que ao serem expostos a este tipo de agressividade, podem sofrer alto risco de degradação. Inicialmente foi coletada em uma siderúrgica, amostras de escórias de aciaria elétrica, a qual foi submetida ao processo de moagem pro micronização. Foram realizadas dosagens de argamassas constituídas de CP V ARI RS e escória de aciaria elétrica micronizada nos traços 1 : 1,5, 1 : 3 e 1 : 4,5. Nesses respectivos traços, o CP V ARI RS foi substituído pela escória de aciaria elétrica micronizada nos percentuais de 0%, 10% e 34%. Seqüencialmente, foram moldados corpos-de-prova e avaliados pelo método de penetração de íons cloreto da ASTM. Para a análise dos resultados, foi utilizado a Anova. A Anova mostrou que, ao substituir CP V ARI RS por escória de aciaria elétrica micronizada, existe uma influência significativa do teor de adição de escória e do traço sobre os resultados da penetração íons cloreto em corpos-de-prova de argamassa.

 

The research was to evaluate the performance of mortar produced with Portland cement mixtures (CP V ARI RS) and micronized electrical steel making slag against the attack of chloride ions. The relevance of the study is based on the need to evaluate the durability of concrete / mortar when they are exposed to this kind of aggression, can suffer a high risk of degradation. Initially it was collected in a steelmaking, samples of electrical steel making slag, which has undergone to the process of milling by micronization. Mortars were performed test of incorporated CP V ARI RS and micronized electrical steel making slag in percentual 1: 1.5, 1: 3 and 1: 4,5. In their mixes, CP V ARI RS was replaced by micronized electric steel making slag in percentage of 0%, 10% and 34%. Sequentially, were molded specimens and evaluated by the method of ASTM. For the analysis of the results, ANOVA was used. Anova showed that, when replacing CP V ARI RS by micronized electric steel making slag, there is a significant influence of the percentage and mixes interaction on the results of chloride-ion penetration in specimens of mortar.

Keywords

Escória de aciaria micronizada; Ataque íons cloreto; Argamassas.

Micronized steel making slag; Chloride ions attack; Mortars.

How to refer

Polisseni, Antônio Eduardo. ESCÓRIA DE ACIARIA ELÉTRICA MICRONIZADA: DESEMPENHO DE ARGAMASSAS FRENTE AO ATAQUE ÍONS CLORETO , p. 2496-2506. In: 65º Congresso ABM, Rio de Janeiro, 2010.
ISSN: 2594-5327 , DOI 10.5151/2594-5327-16476