Proceedings of the Ironmaking, Iron Ore and Agglomeration Seminars


ISSN 2594-357X

37º Redução e 8º Minério de Ferro vol. 2, num.2 (2007)


Title

IMPLANTAÇÃO DO CONTROLE DE PERDA TÉRMICA E % DE ÁREAS FRIAS COMO PARÂMETRO DE CONTROLE DE PROCESSO DO ALTO-FORNO N° 3 DA CSN

INTRODUCTION OF HEAT LOSS CONTROL AND COLD AREA PERCENTAGE AS A PROCESS CONTROL PARAMETER OF CSN/BRAZIL # 3 BLAST FURNACE

DOI

10.5151/2594-357x-12788

Downloads

Abstract

O trabalho tem como objetivo apresentar a implantação do controle de perda térmica e % de áreas frias no Alto-Forno n° 3 da CSN, bem como os impactos gerados no passado e os resultados obtidos. Na reforma do Alto-Forno n° 3 da CSN em 2001, a refrigeração da parede foi substituída de placas para Staves, nos primeiros anos de operação não foi observado a formação de carga inativa, bem como alterações na marcha operacional do forno por este motivo. Em 2006, observou-se pioras na marcha bem como inícios de engaiolamentos e grandes perdas de produção, qualidade e custo. Com isso foi necessário avaliar a implantação de novos parâmetros de processo através de estudo específico. Após concluído estudo foi implantado um controle de perdas térmicas e % de áreas frias como parâmetro de controle de processo. Após implantação dos controles em novembro de 2006 não foi mais observado a ocorrência de engaiolamentos e pioras na operação do forno, deixando assim de ocorrer grandes perdas de produção, qualidade e custo por esta causa. Como conclusão a implantação deste tipo de controle mostrou-se ser bem efetiva diante dos resultados obtidos.

 

This paper aims to present the introduction of heat loss control and percentage of cold area at CSN #3 BF as well as the impacts created in the past and the results. In the furnace reline back in 2001, cooling of the wall was changed from chill plates to stave coolers. In the first years, no skull or any other significant changes were found in the furnace operations because of this modification. In 2006, however, operations became rather erratic, leading to hangings as well as major production, quality and cost losses. Therefore, it became necessary to consider introducing new process parameters, and a specific study was conducted to that end. Upon its completion, a heat loss control and percentage of the cold area as process control parameter was introduced. As a result, as of November 2006 no hangings or any other operating disturbances which might negatively impact the furnace were found. In short, looking at the results attained, implementing this control method proved to be quite an effective tool.

Keywords

Alto-forno; Controle; Perda térmica; Áreas frias.

Blast furnace; Control; Heat loss; Cold area.

How to refer

Monsôres, André José de Souza; Peixoto, Marco Polo da Silva; Fernandes, Heracliton Antônio; Noblat, Sebastião Jorge Xavier; Aguiar, Francisco Nobrega de. IMPLANTAÇÃO DO CONTROLE DE PERDA TÉRMICA E % DE ÁREAS FRIAS COMO PARÂMETRO DE CONTROLE DE PROCESSO DO ALTO-FORNO N° 3 DA CSN , p. 121-128. In: 37º Redução e 8º Minério de Ferro, São Luís - MA, 2007.