Proceedings of the Seminar on Steelmaking, Casting and Non-Ferrous Metallurgy


ISSN 2594-5300

45º Seminário de Aciaria - Internacional vol. 45, num.45 (2014)


Title

INFLUÊNCIA DA PROPORÇÃO ENTRE AS VAZÕES DE OXIGÊNIO E GÁS NATURAL DO SISTEMA DE INJEÇÃO DE UM FORNO ELÉTRICO A ARCO NO CONSUMO DE ENERGIA TOTAL

INFLUENCE OF OXYGEN AND NATURAL GAS RATIO OF AN ELECTRIC ARC FURNACE INJECTION SYSTEM IN TOTAL ENERGY CONSUMPTION

DOI

10.5151/1982-9345-24246

Downloads

Abstract

Em aciarias elétricas, o consumo dos insumos tem impacto importante na composição do custo final do aço, dos quais se destaca o consumo de energéticos utilizados no forno elétrico a arco, que pode representar até 30% do custo operacional de uma aciaria. Para quantificar o aporte desses diferentes tipos de energia é utilizado o indicador de consumo de energia total FEA + FP, que associa fatores de equivalência a cada tipo de energético de forma a transformar sua unidade de medida para a unidade base de kWh/t. Nesse trabalho foi realizado um teste no formato de projeto de experimentos, variando-se as vazões de gás natural e/ou oxigênio em um dos modos de queimador e em três modos de lança a fim de modificar suas proporções O2/GN e avaliar o impacto no consumo de energia total.

 

In electric steelmaking, consumption of inputs plays an important role on the final billet cost, with particular emphasis to the energy consumption in the electric arc furnace, which can represent up to 30% of the operational cost in a melt shop. To quantify the contribution of different types of energy in EAF, it is used the performance indicator of total energy consumption, which associates equivalency factors for each type of energy, so that their measurement unit can be transformed to the base unit kWh/t. In this work, a test was conducted on a design of experiments format, varying the flow of natural gas and/or oxygen in a burner mode and in three lance modes, in order to modify their O2/GN ratio and evaluate the impact in total energy consumption.

Keywords

Energia total; Eficiência energética; Injeção de gases; Processo de FEA

Total energy; Energy efficiency; Gas injection; EAF process

How to refer

Daniel Rossi; Wagner Viana Bielefeldt; Antônio Cezar Faria Vilela. INFLUÊNCIA DA PROPORÇÃO ENTRE AS VAZÕES DE OXIGÊNIO E GÁS NATURAL DO SISTEMA DE INJEÇÃO DE UM FORNO ELÉTRICO A ARCO NO CONSUMO DE ENERGIA TOTAL , p. 1992-2002. In: 45º Seminário de Aciaria - Internacional, Porto Alegre - Brasil, 2014.
ISSN: 2594-5300 , DOI 10.5151/1982-9345-24246