Abstract

Neste trabalho foi investigada a influencia do tratamento térmico de alívio de tensões na tenacidade ao impacto de juntas soldadas com arame tubular rutílico. Uma junta de aço estrutural com 60 mm de espessura foi soldada na posição vertical ascendente. Uma metade desta junta foi tratada termicamente para alívio de tensões, e a outra mantida como soldada. Foi realizado ensaio de impacto Charpy-V em ambas condições. Comparando os resultados, observa-se uma queda da tenacidade após tratamento térmico. Analisando as superfícies dos corpos de prova Charpy-V rompidos pode-se observar uma maior fração de superfície característica de fratura frágil nos CP’s tratados termicamente em relação aos CP’s mantidos como soldado. Não foi identificada mudança significativa na microestrutura obtida por microscopia óptica e não foi identificada precipitação na escala MEV após tratamento térmico, exigindo um estudo mais criterioso, utilizando microscópio eletrônico de transmissão (MET).

 

On this paper was investigated the influence of postweld heat treatment in impact toughness of joints welded with rutile flux-cored. One joint of structural steel with 60 mm thickness was welded on an ascending vertical position. Half of this joint was heat treated for stress relief, and the other half was kept as welded. Charpy-V impact test was carried out on both conditions. Comparing the results, it can be observed a decrease on the toughness after the heat treatment. Analyzing the surfaces of Charpy-V test broken samples it can be observed a higher percentage of characteristic surface of brittle fracture on the specimens heat treated than the others. Significant change was not identified in the microstructure analyzed on an optic microscopy and was not identified precipitation on SEM scale after heat treatment, demanding this way a more detailed study, using transmission electron microscopy (TEM).

Keywords

Arame tubular rutílico; Tratamento térmico; Alívio de tensões; Tenacidade ao impacto.

Rutile flux-cored wire; Heat treatment; Stress relief; Impact toughness.

How to refer

Júnio, José Mauro Moraes. INFLUÊNCIA DO TRATAMENTO TÉRMICO DE ALÍVIO DE TENSÕES NA TENACIDADE AO IMPACTO DE AÇOS ESTRUTURAIS SOLDADOS COM ARAME TUBULAR RUTÍLICO , p. 4011-4022. In: 62º Congresso anual da ABM, Vitória, 2007.
ISSN: 2594-5327 , DOI 10.5151/2594-5327-0434