A Companhia Siderúrgica de Tubarão – CST já nasceu, no início dos anos 80, como autoprodutora de energia elétrica, ou seja, com geração termelétrica interna (baseada em gases siderúrgicos) suficiente para atender parte de seu consumo interno. Desde então houve necessidade da operação de um Sistema de Rejeição de Cargas - SRC para resguardar as unidades operacionais mais importantes da CST em caso de distúrbio na concessionária local. Este sistema se baseia, resumidamente, em assegurar, via o corte de cargas antecipadamente selecionadas, que em caso de distúrbio externo a geração elétrica interna será condizente com o consumo interno, ou seja, assegurar que não haverá sobrecarga nas centrais termelétricas e um conseqüente blecaute. O atual SRC da CST está em operação há mais de vinte anos e visto que a CST ampliou sua demanda elétrica interna de cerca de 110 MW para os atuais 210 MW e a geração de 102 MW para os atuais 268 MW (sem considerar os 34 MW mecânicos de sopro para o Alto Forno 1), o atual sistema encontra-se insuficiente para resguardar déficits de geração que ocorrem quando da falta de gás siderúrgico ou parada de unidade de geração. Assim, o objetivo deste trabalho é mostrar ao público da ABM as linhas gerais do novo sistema de rejeição de cargas sem aprofundamentos técnicos inadequados.

 

The Companhia Siderúrgica de Tubarão – CST was born, in the beginning of 80s, as an auto producer, so CST was always able to produce electric energy for its own consumption, reducing its dependence from the local energy supplier. This generation is based on power plants, powered by metallurgic fuels (Blast Furnace Gas and Coke Oven Gas). Since this beginning, CST needed a Load Shedding System (SRC, Portuguese abbreviation) to keep the most important CST loads in safety in case of a grid external outage. This system is based on an automatic mechanism to assure (by preset electric loads to shed, prior to the event) that the amount of internal load can be handle by the internal generation, avoiding a power plant overload and a following blackout. The actual SRC is twenty years old and CST, in the mean while, has enhanced a lot its amount of consumption and generation. This situation turned the actual SRC not more able to accomplish its basic function without constrains. Thus, this work has as a goal to show to ABM’s public the guide lines of CST’s new Load Shedding System, without deep in unnecessary technical issues.

Keywords

Carga, Rejeição, CST

Load, Shedding, CST

How to refer

Silva, Helder Vieira da; Souza, Ricardo de Mello. NOVO SISTEMA DE REJEIÇÃO DE CARGAS DA CST , p. 255-261. In: 25º Seminário de Balanços Energéticos Globais e Utilidades e 11º Encontro de Produtores e Consumidores de Gases Industriais, Florianópolis - SC, 2004.
ISSN: 2594-3626 , DOI 10.5151/2594-3626-0027