Proceedings of ABM Annual Congress


ISSN 2594-5327

75° Congresso Anual da ABM vol. 75, num.75 (2022)


Title

NÍVEL DE INTEGRIDADE DE SEGURANÇA (SIL) APLICADO AO PROJETO DE TRANSPORTADOR DE CORREIA

SAFETY INTEGRITY LEVEL (SIL) APPLIED TO THE BELT CONVEYOR DESIGN

DOI

10.5151/2594-5327-34886

Downloads

Abstract

NESTE TRABALHO, ESTUDOU-SE ALGUNS DOS PERIGOS E RISCOS OPERACIONAIS RELACIONADOS A TRANSPORTADORES DE CORREIA E FOI PROPOSTO A INSTALAÇÃO DE INTERTRAVAMENTO POR UMA FUNÇÃO INSTRUMENTADA DE SEGURANÇA, QUE AO DETECTAR CARGA ALTA NO TRANSPORTADOR, INTERROMPA A DOSAGEM FECHANDO UMA VÁLVULA GUILHOTINA. APLICOU-SE O MÉTODO HAZOP PARA IDENTIFICAÇÃO DE PERIGOS E O MÉTODO LOPA PARA QUANTIFICAÇÃO DOS RISCOS. NO PROJETO DA FUNÇÃO, ADOTOU-SE AS RECOMENDAÇÕES DO CICLO DE VIDA DE SEGURANÇA DA NORMA IEC 61511-1, O MÉTODO BASEADO EM DIAGRAMAS DE BLOCOS DE CONFIABILIDADE, AS FÓRMULAS SIMPLIFICADAS DA NORMA VDI/VDE 2180-4 E PLANILHA ELETRÔNICA PARA CÁLCULOS. PARA DETERMINAÇÃO DA PROBABILIDADE DE FALHA DOS COMPONENTES, CONSIDERARAM-SE PARÂMETROS TAIS COMO LAMBDADU (TAXA DE FALHAS PERIGOSAS NÃO DETECTADAS), ARQUITETURA DE VOTAÇÃO E FREQUÊNCIA DE TESTES. A CONFIABILIDADE DA FUNÇÃO FOI ATINGIDA, OBTENDO-SE SIL1 E FATOR DE REDUÇÃO DE RISCO 40, PROBABILIDADE DE FALHA NA DEMANDA DE 2,48E-02 POR ANO

 

IN THIS WORK, SOME OF THE DANGERS AND OPERATIONAL RISKS RELATED TO BELT CONVEYORS WERE STUDIED AND IT WAS PROPOSED TO INSTALL AN INTERLOCK BY AN INSTRUMENTED SAFETY FUNCTION, WHICH, WHEN DETECTING A HIGH LOAD ON THE CONVEYOR, INTERRUPTS THE DOSAGE BY CLOSING A GUILLOTINE VALVE. THE HAZOP METHOD WAS APPLIED TO IDENTIFY HAZARDS AND THE LOPA METHOD TO QUANTIFY THE RISKS. IN THE FUNCTION DESIGN, THE SAFETY LIFECYCLE OF THE IEC 61511-1 STANDARD WAS ADOPTED, THE METHOD BASED ON THE RELIABILITY BLOCK DIAGRAMS, THE SIMPLIFIED FORMULAS OF THE VDI/VDE 2180-4 STANDARD AND SPREADSHEET ELECTRONIC FOR CALCULATIONS. TO DETERMINE THE PROBABILITY OF COMPONENTS FAILURE, PARAMETERS SUCH AS LAMBDADU (DANGEROUS UNDETECTED FAILURE RATES), VOTING ARCHITECTURE AND TESTS INTERVAL. THE RELIABILITY OF THE FUNCTION WAS ACHIEVED, OBTAINING SIL1 WITH A RISK REDUCTION FACTOR 40, PROBABILITY OF FAILURE ON DEMAND OF 2.48E-02 PER YEAR

Keywords

Transportador de Correia; SIL; Nível de Integridade de Segurança

Belt Conveyor; SIL; Safety Integrity Level

How to refer

Guedes, Heliliano Carlos Sartori; Siqueira, Fernanda; Valezin, Pedro; Lima, Roberta. NÍVEL DE INTEGRIDADE DE SEGURANÇA (SIL) APLICADO AO PROJETO DE TRANSPORTADOR DE CORREIA , p. 1358-1368. In: 75° Congresso Anual da ABM, São Paulo, 2022.
ISSN: 2594-5327 , DOI 10.5151/2594-5327-34886