Proceedings of the Seminar on Energy, Utilities and Industrial Gases


ISSN 2594-3626

Title

OTIMIZAÇÃO DO CONSUMO DE GÁS NO AQUECIMENTO DE DISPOSITIVOS REFRATÁRIOS ATRAVÉS DO CONTROLE ESTEQUIOMÉTRICO NA COMPANHIA SIDERÚRGICA DO PECÉM

OPTIMIZATION OF THE CONSUMPTION OF NATURAL GAS IN THE REFRACTORY HEATING DEVICES THROUGH THE STOICHIOMETRIC CONTROL AT THE PECÉM STEEL COMPANY

DOI

10.5151/2594-3626-31739

Downloads

Abstract

"A necessidade de adequação dos equipamentos de secagem e aquecimento de materiais refratários devido a substituição do fornecimento de gás natural sintético (GNS) pelo gás natural (GN), de menor preço, na planta de lingotamento contínuo da Companhia Siderúrgica de Pecém, possibilitou ganhos adicionais advindos do aumento da eficiência na queima, por meio de um controle das vazões do combustível e do comburente baseado na correta relação estequiométrica. A preparação e os testes foram feitos previamente em um secador de distribuidores e depois as modificações foram estendidas aos dois aquecedores de distribuidores, todos eles com consumo de 37 m3/h gás e poder calorífico de 57.3 MJ/m3. A análise dos resultados no consumo de gás, decorrente desta modificação foi de 20% nos aquecedores e de 40 % para o secador de distribuidores. O volume mensal de gás economizado foi de 6364,5 m3 para o Secador, 23040 m3 para o aquecedor 1 e de 14190 m3 para o aquecedor 2. "

 

"Due the necessity to adapt the Tundish Dryer and Tundish Pre-Heater devices during the substitution of the Synthetic Natural Gas supplying for the Natural Gas, which is cheaper, at the continuous casting plant of Companhia Siderúrgica de Pecém, have brought additional gains through the increase in burning efficiency , by means of flow control of the fuel and of the oxidizer based on the best stoichiometric ratio. All the preparation and tests were previously done in a Tundish Dryer, afterward these modifications were extended to the two Tundish Pre-heaters, all of them with gas consumption of 37 m3/h and a heating power of 57.3 MJ/ m3. The reducing at the gas consumption resulting from this modification was 20% at the Tundish Pre-heaters and 40% at the Tundish Dryer. The monthly volume of gas saved was 6364.5 m3 for the Tundish Dryer, 23040 m3 for the Tundish Pre-heater 1 and 14190 m3 for Tundish Pre-heater 2. "

Keywords

Estequiometria; Controle de processos; Gás Natural; Lingotamento Contínuo.

Stoichiometric; Process control; Natural gas; Continuous Casting.

How to refer

Silva, Charlie Denis Cordeiro; Gouveia Filho, Marcos Daniel. OTIMIZAÇÃO DO CONSUMO DE GÁS NO AQUECIMENTO DE DISPOSITIVOS REFRATÁRIOS ATRAVÉS DO CONTROLE ESTEQUIOMÉTRICO NA COMPANHIA SIDERÚRGICA DO PECÉM , p. 39-50. In: 33° Encontro de Produtores e Consumidores de Gases Industriais, São Paulo, 2018.
ISSN: 2594-3626 , DOI 10.5151/2594-3626-31739