Proceedings of the Seminar on Energy, Utilities and Industrial Gases


ISSN 2594-3626

Title

OTIMIZAÇÃO DO CONTROLE MICROBIOLÓGICO ATRELADO A REDUÇÃO DE CUSTO EM TRATAMENTO DE ÁGUA PARA TORRES DE RESFRIAMENTO COM O USO DA TECNOLOGIA SPECTRUS OX1276TM

OPTIMIZATION OF MICROBIOLOGICAL CONTROL LINKED TO COST REDUCTION IN WATER TREATMENT FOR COOLING TOWERS USING SPECTRUS OX1276TM TREATMENT TECHNOLOGY

DOI

10.5151/2594-3626-40961

Downloads

Abstract

TORRES DE RESFRIAMENTO SãO EQUIPAMENTOS DE TROCA TéRMICA ESSENCIAIS PARA AS USINAS SIDERúRGICAS E GRANDE PARTE DOS PROCESSOS INDUSTRIAIS. UM RíGIDO CONTROLE DA QUALIDADE DA áGUA DE RESFRIAMENTO é IMPRESCINDíVEL PARA A MANUTENçãO DA EFICIêNCIA E INTEGRIDADE DOS EQUIPAMENTOS QUE A UTILIZAM. DENTRE OS DIVERSOS PARâMETROS QUE DETERMINAM A PERFORMANCE DO TRATAMENTO QUíMICO DE UMA TORRE DE RESFRIAMENTO, O CONTROLE MICROBIOLóGICO ESTá ENTRE OS PRINCIPAIS, POIS QUANDO PREJUDICADO, PODE CAUSAR DEPOSIçãO E/OU INCRUSTAçãO, CORROSãO E PROLIFERAçãO MICROBIOLóGICA DESCONTROLADAS. COMO CONSEQUêNCIA, A DIMINUIçãO DO RENDIMENTO DOS PROCESSOS, ASSIM COMO A POSSíVEL PARADA OPERACIONAL PARA LIMPEZA E DESCONTAMINAçãO DO SISTEMA OU SUBSTITUIçãO DOS EQUIPAMENTOS E TUBULAçõES PODEM SER ACARRETADOS. DIANTE DA NECESSIDADE DE OTIMIZAçãO DO CONTROLE MICROBIOLóGICO DA TORRE DE RESFRIAMENTO DA CENTRAL TERMELéTRICA (CTE) DA ARCELORMITTAL PECéM (AMPE), A VEOLIA REALIZOU UM TESTE DE 46 DIAS COM O BIOCIDA OXIDANTE SPECTRUS OX1276TM (ÁCIDO ISOCIANúRICO ATIVADO) E AVALIOU OS EFEITOS SOBRE CLORETOS, CLORO LIVRE, LAMINOCULTIVO E PH DA áGUA DE RECIRCULAçãO. DIANTE DOS RESULTADOS OBTIDOS, A TECNOLOGIA DE CONTROLE MICROBIOLóGICO PROPOSTA SE MOSTROU NãO APENAS VIáVEL OPERACIONALMENTE, COMO TAMBéM FINANCEIRAMENTE, SENDO VALIDADA E IMPLEMENTADA NO PROGRAMA DE TRATAMENTO QUíMICO DA TORRE, EM SUBSTITUIçãO AO HIPOCLORITO DE SóDIO

 

COOLING TOWERS ARE ESSENTIAL HEAT EXCHANGE EQUIPMENT FOR STEEL PLANTS AND MOST INDUSTRIAL PROCESSES. STRICT QUALITY CONTROL OF THE COOLING WATER IS INDISPENSABLE TO MAINTAIN THE EFFICIENCY AND INTEGRITY OF THE EQUIPMENT USING IT. AMONG THE VARIOUS PARAMETERS THAT DETERMINE THE PERFORMANCE OF THE CHEMICAL TREATMENT OF A COOLING TOWER, MICROBIOLOGICAL CONTROL IS AMONG THE MAIN ONES, AS WHEN IMPAIRED, IT CAN CAUSE DEPOSITION AND/OR FOULING, CORROSION AND UNCONTROLLED MICROBIOLOGICAL PROLIFERATION. THEREFORE, A REDUCTION IN PROCESS PERFORMANCE, AS WELL AS POSSIBLE OPERATIONAL STOPPAGE FOR CLEANING AND DECONTAMINATION OF THE SYSTEM OR REPLACEMENT OF EQUIPMENT AND PIPING, MAY BE CAUSED. DUE TO THE NEED TO OPTIMIZE THE MICROBIOLOGICAL CONTROL OF THE COOLING TOWER OF THE ARCELORMITTAL PECéM (AMPE) POWER PLANT (CTE), VEOLIA CARRIED OUT A 46-DAY TEST WITH THE OXIDIZING BIOCIDE SPECTRUS OX1276TM (ACTIVATED ISOCYANURIC ACID) AND EVALUATED THE EFFECTS ON CHLORIDES , FREE CHLORINE, DEEP SLICE AND PH OF COOLING WATER. GIVEN THE RESULTS, THE PROPOSED MICROBIOLOGICAL CONTROL TECHNOLOGY PROVED TO BE NOT ONLY OPERATIONALLY, BUT ALSO FINANCIALLY FEASIBLE, BEING VALIDATED AND IMPLEMENTED IN THE TOWER'S CHEMICAL TREATMENT PROGRAM, REPLACING SODIUM HYPOCHLORITE

Keywords

Torre de resfriamento; Tratamento de água; Biocida oxidante; Controle microbiológico

Cooling tower; Water treatment; Oxidizing biocide; Microbiological control.

How to refer

NETO, FRANCISCO DAS CHAGAS SILVA; MELO, ANA LÍDIA TOMAZ DE; MARUCCI, AUGUSTO LUIS. OTIMIZAÇÃO DO CONTROLE MICROBIOLÓGICO ATRELADO A REDUÇÃO DE CUSTO EM TRATAMENTO DE ÁGUA PARA TORRES DE RESFRIAMENTO COM O USO DA TECNOLOGIA SPECTRUS OX1276TM , p. 136-145. In: 43º Seminário de Energia, Utilidades e Transição Energética, São Paulo, Brasil, 2024.
ISSN: 2594-3626 , DOI 10.5151/2594-3626-40961