Powered by Blucher Proceedings

Proceedings of ABM Annual Congress


ISSN 2594-5327

60º Congresso Anual da ABM Vol. 60 , num. 60 (2005)


Title

REMOÇÃO DE MANGANÊS DE EFLUENTES COM UTILIZAÇÃO DO PERÓXIDO DE HIDROGÊNIO

REMOVAL OF MANGANESE FROM EFFLUENTS USING HYDROGEN PEROXIDE

Authorship

DOI

10.5151/2594-5327-2005-13402-0096

Downloads

266 Downloads

Abstract

O trabalho investigou a remoção de manganês (II) de efluentes utilizando os oxidantes: oxigênio, reagente Fenton e peróxido de hidrogênio, para procurar dentre estes um processo que fosse mais eficiente do que o de simples precipitação do hidróxido de manganês. Ensaios de tratamento de soluções sintéticas de Mn (II) foram realizados em pH de 7 a 10, a temperatura ambiente e com um tempo de oxidação de 5,15 e 30 minutos seguido de um tempo de 15 minutos para neutralização. Foi utilizado peróxido de hidrogênio em dosagem com excesso de 100% e 200%+sobre a estequiométrica, para a reação: Mn2+ (aq) + H2O2 (aq) = MnO2(s) + 2 H (aq). Dentre os testes realizados, ambos o peróxido de hidrogênio e o reagente Fenton mostraram-se bastante eficientes na remoção de manganês, permitindo atingir concentrações finais desse metal inferiores a 0,3 mg/L, a temperatura ambiente em valores de pH inferiores aos necessários para a precipitação sem oxidante, ou com O2.

 

In order to remove metals from waters and aqueous effluents, generally are employed traditional methods which involve neutralization, hydrolysis and precipitation of hydroxides using a base. Manganese must be removed from waters and aqueous effluents down to a concentration limited by Brazilian law which is of 0.1 mg/L for waters and 1.0 mg/L for aqueous effluents. The work carried out herein investigated the removal of manganese (II) using the following oxidants: oxygen, hydrogen peroxide, and Fenton reagent, with the aim to identify a process that could be more efficient than the simpler hydroxide precipitation. Results are discussed of experiments made with synthetic solutions of 1000 mg/L manganese (II) with the objective of developing a route that could favour the removal of that metal to the levels established by Brazilian environmental law (resolution CONAMA 20 / 1986). The experiments were conducted in pH 7 to 10, at temperature ambient and 80 oC, with reaction times of 5, 15 and 30 minutes. Hydrogen peroxide was used in excess levels of 100 and 200% for the reaction: Mn2+ (aq) + H2O2 (aq)

Keywords

Tratamento de efluentes; Precipitação de manganês; Peróxido de hidrogênio

Manganese; Hydrogen peroxide; Fenton’s reagent; Chemical oxidation; Effluents; Waters

How to cite

Santos, Juliana Santos dos; Teixeira, Luiz Alberto Cesar. REMOÇÃO DE MANGANÊS DE EFLUENTES COM UTILIZAÇÃO DO PERÓXIDO DE HIDROGÊNIO, p. 940-947. In: 60º Congresso Anual da ABM, Belo Horizonte, 2005.
ISSN: 2594-5327, DOI 10.5151/2594-5327-2005-13402-0096