Proceedings of the Ironmaking, Iron Ore and Agglomeration Seminars


ISSN 2594-357X

Title

THE THERNAL BALANCE TEST REPORT FOR BF HOT STOVES IN SHOUGANG JINGTANG UNITED IRON & STEEL CO., LTD

THE THERNAL BALANCE TEST REPORT FOR BF HOT STOVES IN SHOUGANG JINGTANG UNITED IRON & STEEL CO., LTD

DOI

10.5151/2594-357X-22299

Downloads

Abstract

In order to investigate the energy saving effect of High Radiative Coating Technology (HRC) on No.2 5,500 m3 BF in Shougang Jingtang United Iron & Steel Co., Ltd (Jingtang Co.), the energy-saving thermal diagnostic test and quantitative analysis comparison of thermal process are carried out between the No.2 5,500 m3 BF with HRC and No.1 5,500 m3 BF without HRC (each BF is equipped with four hot blast stoves). The diagnostic result shows that, when average blast temperature of the two BF are almost the same (No. 2 BF is only 1°C higher than No. 1 BF), compared with No.1 BF, the effective thermal utilization rate of No. 2 BF increased; the thermal efficiency increased 2.84%; the heat taken away by exhaust gas decreased 2.47%; the fuel gas consumption decreased 7.07%.

 

In order to investigate the energy saving effect of High Radiative Coating Technology (HRC) on No.2 5,500 m3 BF in Shougang Jingtang United Iron & Steel Co., Ltd (Jingtang Co.), the energy-saving thermal diagnostic test and quantitative analysis comparison of thermal process are carried out between the No.2 5,500 m3 BF with HRC and No.1 5,500 m3 BF without HRC (each BF is equipped with four hot blast stoves). The diagnostic result shows that, when average blast temperature of the two BF are almost the same (No. 2 BF is only 1°C higher than No. 1 BF), compared with No.1 BF, the effective thermal utilization rate of No. 2 BF increased; the thermal efficiency increased 2.84%; the heat taken away by exhaust gas decreased 2.47%; the fuel gas consumption decreased 7.07%.

Keywords

Blast furnace hot stove; High radiative coating; Thermal efficiency diagnosis; Energy saving effect.

Blast furnace hot stove; High radiative coating; Thermal efficiency diagnosis; Energy saving effect.

How to refer

Daqiang, Cang; Xianbin, Ai; Weidong, Zhang; Haibo, Shen; Huimin, Zhou; Chuansheng, Sun; Yizhou, Liu; Yanfei., Zhai. THE THERNAL BALANCE TEST REPORT FOR BF HOT STOVES IN SHOUGANG JINGTANG UNITED IRON & STEEL CO., LTD , p. 1821-1827. In: 42º Seminário de Redução de Minério de Ferro e Matérias-primas / 13º Seminário Brasileiro de Minério de Ferro / 6th International Congress on the Science and Technology of Ironmaking, Rio de Jabeiro, 2012.
ISSN: 2594-357X , DOI 10.5151/2594-357X-22299