Anais dos Seminários de Redução, Minério de Ferro e Aglomeração


ISSN 2594-357X

21° Simpósio de Mineração vol. 21, num.21 (2022)


Título

ANALISADOR DE TEOR DE SÍLICA POR ANÁLISE DE IMAGEM PARA CONTROLE AVANÇADO DE PROCESSO

SILICA CONTENT ANALYZER BY IMAGE ANALYSIS FOR ADVANCED PROCESS CONTROL

DOI

10.5151/2594-357X-34220

Downloads

Baixar Artigo 17 Downloads

Resumo

O OBJETIVO DO TRABALHO FOI HOMOLOGAR UM ANALISADOR DE TEOR DE SÍLICA VIA ANÁLISE DE IMAGEM PARA CONTROLE AVANÇADO E OTIMIZAÇÃO DO PROCESSO DE FLOTAÇÃO EM COLUNA DA CSN MINERAÇÃO. A METODOLOGIA BÁSICA DO TRABALHO CONSISTIU NA PARAMETRIZAÇÃO E CONSTRUÇÃO DO ALGORITMO DO EQUIPAMENTO, TESTES DE COMPARAÇÃO COM LABORATÓRIO QUÍMICO E TESTES INDUSTRIAIS. OS RESULTADOS QUALITATIVOS PERCEBIDOS FORAM A MAIOR PREVISIBILIDADE E ESTABILIDADE DO PROCESSO, ATUAÇÃO MAIS RÁPIDA NA FLOTAÇÃO E MAIOR CHANCE DE ALCANÇAR AS METAS DE TEOR DE SÍLICA DO CLIENTE. OS RESULTADOS QUANTITATIVOS SE RESUMEM EM UMA BOA CORRELAÇÃO COM OS RESULTADOS DO LABORATÓRIO QUÍMICO, R² = 86% DA ANÁLISE DE REGRESSÃO LINEAR. REDUÇÃO DE 22% NA VARIABILIDADE DO TEOR DE SÍLICA DO CONCENTRADO DA FLOTAÇÃO E REDUÇÃO DE 10% NA DOSAGEM DO REAGENTE AMINA. FOI OBSERVADO UM POTENCIAL GANHO NA REDUÇÃO DE 50% NO NÚMERO DE ANÁLISES QUÍMICAS DE ROTINA DO LABORATÓRIO. COMO CONCLUSÃO DO TRABALHO O EQUIPAMENTO MOSTROU GANHOS EXPRESSIVOS NO CONSUMO DE REAGENTE E ESTABILIDADE DO PROCESSO DE FLOTAÇÃO EM COLUNA DA CSN MINERAÇÃO.

 

THE OBJECTIVE WAS TO APPROVE A SILICA CONTENT ANALYZER BY IMAGE ANALYSIS FOR ADVANCED CONTROL AND OPTIMIZATION OF THE CSN MINERAÇÃO COLUMN FLOTATION PROCESS. THE METHODOLOGY CONSISTED OF PARAMETERIZATION AND CONSTRUCTION OF THE EQUIPMENT'S ALGORITHM, COMPARISON TESTS WITH CHEMICAL LABORATORY AND INDUSTRIAL TESTS. THE QUALITATIVE RESULTS WERE GREATER PREDICTABILITY AND STABILITY OF THE PROCESS, FASTER FLOTATION INTERFERENCE AND GREATER CHANCE OF REACHING THE CLIENT SILICA CONTENT. THE QUANTITATIVE RESULTS ARE SUMMARIZED IN A GOOD CORRELATION WITH THE CHEMICAL LABORATORY RESULTS, R² = 86% OF THE LINEAR REGRESSION ANALYSIS. THE VARIABILITY OF FLOTATION CONCENTRATE SILICA CONTENT WAS REDUCE IN 22% AND THE DOSAGE OF THE AMINE REAGENT WAS REDUCE 10%. THE NUMBER OF THE LABORATORY ROUTINE CHEMICAL ANALYSIS HAS A POTENTIAL GAIN TO REDUCE 50%. AS A CONCLUSION, THE EQUIPMENT SHOWED SIGNIFICANT GAINS IN REAGENT CONSUMPTION AND STABILITY OF THE CSN MINERAÇÃO COLUMN FLOTATION PROCESS.

Palavras-chave

ANALISADOR DE TEOR DE SÍLICA; ANÁLISE DE IMAGEM; FLOTAÇÃO EM COLUNA; CONTROLE AVANÇADO DE PROCESSO.

SILICA CONTENT ANALYZER; IMAGE ANALYSIS; COLUMN FLOTATION; ADVANCED PROCESS CONTROL.

Como citar

Mantilla, Edgar Rodo. ANALISADOR DE TEOR DE SÍLICA POR ANÁLISE DE IMAGEM PARA CONTROLE AVANÇADO DE PROCESSO , p. 46-61. In: 21° Simpósio de Mineração, São Paulo, 2022.
ISSN: 2594-357X , DOI 10.5151/2594-357X-34220