Anais do Enemet - Encontro Nacional de Estudantes de Engenharia Metalúrgica, de Materiais e de Minas


ISSN 2594-4711

18° ENEMET vol. 18, num.18 (2018)


Título

IDENTIFICAÇÃO E ANÁLISE DE INCLUSÕES NÃO METÁLICAS EM AÇOS INOXIDÁVEIS FERRÍTICOS VIA ESPECTROMETRIA DE EMISSÃO ÓPTICA COM SISTEMA SPARK-DAT

IDENTIFICATION AND ANALYSIS OF NON-METALLIC INCLUSIONS IN FERRITIC STAINLESS STEELS THROUGH OPTICAL EMISSION SPECTROMETRY WITH SPARK-DAT SYSTEM

DOI

10.5151/2594-4711-31599

Downloads

Baixar Artigo 556 Downloads

Resumo

A detecção rápida do surgimento de inclusões durante a produção do aço permite controle e correções ainda na Aciaria, garantindo a qualidade e aplicação final do produto. Diante disso, este trabalho teve como propósito desenvolver e verificar a efetividade de métodos de análise de inclusões via espectrometria óptica com sistema Spark-DAT, que permite a determinação rápida dos tipos, número e tamanho das inclusões, simultaneamente às análises de composição química, já realizadas pela espectrometria óptica tradicional. Por conseguinte, essa técnica representa avanço na área, complementando métodos convencionais de microscopia, não aplicáveis em linhas de produção, devido principalmente ao longo tempo requerido de análise. A pesquisa foi realizada em parceria com a Aperam South America, sendo utilizado o Espectrômetro Thermo ARL iSpark 8860, e analisadas amostras de aços inoxidáveis ferríticos. Para validação dos métodos, comparou-se os resultados com análises por microscopia eletrônica de varredura, sendo confirmada a confiabilidade do programa Spark-DAT em caracterizar as inclusões presentes no aço. Houve compatibilidade entre as técnicas, quanto à composição química, tamanho e número de inclusões, possibilitando o uso do método para análises qualitativas de inclusões não metálicas no aço.

 

The quick detection of the appearance of inclusions during the steel production allows control and corrections still in the Melt Shop, guaranteeing the quality and final application of the product. The purpose of this work was to develop and verify the effectiveness of methods of inclusion analysis using optical spectrometry with Spark-DAT system, which allows quick determination of the types, number and size of the inclusions simultaneously with the analyzes of chemical composition, already performed by traditional optical spectrometry. Therefore, this technique represents advance in the field, complementing conventional microscopy methods, not applicable in production lines, mainly due to the long time required for analysis. The research was made in partnership with Aperam South America, using the Thermo ARL iSpark 8860 Spectrometer, and samples of ferritic stainless steels were analyzed. For the validation of the methods, the results were compared with scanning electron microscopy analysis, confirming the reliability of the Spark-DAT system in characterizing the inclusions present in steel. There was compatibility between the techniques, regarding the chemical composition, size and number of inclusions, making possible the use of the method for qualitative analysis of nonmetallic inclusions in steel.

Palavras-chave

Inclusões; Espectrometria; Spark-DAT; Aços Inoxidáveis Ferríticos.

Inclusions; Spectrometry; Spark-DAT; Ferritic Stainless Steels.

Como citar

Faria, Lúrima Uane Soares; Silva, Jaqueline Lacerda da; Alvarenga, Valdeci Paula; Monteiro, Robson Chateaubriand; Cunha, Márcio Nascimento. IDENTIFICAÇÃO E ANÁLISE DE INCLUSÕES NÃO METÁLICAS EM AÇOS INOXIDÁVEIS FERRÍTICOS VIA ESPECTROMETRIA DE EMISSÃO ÓPTICA COM SISTEMA SPARK-DAT , p. 60-71. In: 18° ENEMET, São Paulo, 2018.
ISSN: 2594-4711 , DOI 10.5151/2594-4711-31599